6.3  IDENTIFICATION

 

TEXT

 

It is possible to add a standard identification text (NAME) to all messages sent out by 
the Mobeye CML2275. The alarm messages are a combination of the name and the 
alarm text. A user defined identification has a length of maximum 20 characters. The 
default identification text is 

‘Mobeye’. 

 
SMS command identification text: 

NAME: 

 

example: 

1111 NAME:my Mobeye device 

6.4  ALARM TEXTS 

Unique alarm texts can be programmed into the Mobeye CML2275. User defined texts 
have a maximum length of 20 characters.  
Following default texts are programmed: 
Text 1 (low temperature 1 alarm): 

Temperature 1 too low: 

Text 2 (high temperature 1 alarm): 

Temperature 1 too high: 

Text 3 (temperature 1 restored): 

Temperature 1 OK 

Text 4 (low temperature 2 alarm): 

Temperature 2 too low: 

Text 5 (high temperature 2 alarm): 

Temperature 2 too high: 

Text 6 (temperature 2 restored): 

Temperature 2 OK 

Text 7 (input 1): 

 

Alarm 1 

Text 8 (input 2): 

 

Alarm 2 

Text 9 (power failure): 

Power failure 

Text 10 (power restoration): 

Power restored 

NB: text 9 and 10 are only valid at POWERMESSAGE set to 

‘ALARM’. 

 

SMS command text low temperature 1 alarm:  

TEXT1:

 

SMS command text high temperature 2 alarm: 

TEXT2:

 

Similar for TEXT3 ... TEXT10 
 

 

example: 

 1111 TEXT4:freezer too cold

 

6.5  SMS ON/OFF 

By default, the Mobeye CML2275 sends alarm notifications via text message and calls 
(you will hear a beep signal) to the preset contact persons. By turning off the SMS, the 
unit will only call after a triggered input.  

Содержание ThermoGuard TwinLog CML2275

Страница 1: ...USER MANUAL ThermoGuard TwinLog CML2275 SW version 4 n...

Страница 2: ......

Страница 3: ...eat and water splashing Not intended for external use The guidelines for the battery usage must be regarded Do not expose the device to strong vibrations Do not let it fall from height Do not use in a...

Страница 4: ...onnect a device to the output 13 4 3 Control the output via SMS command 14 4 4 Output behaviour 14 5 Configuration 15 5 1 Program mode 15 5 2 The security code 16 5 3 Programming the settings by SMS 1...

Страница 5: ...18 Output behaviour 25 6 19 Automatic arming disarming 25 6 20 Buttonlock 26 6 21 Test message 26 6 22 Additional log functions in the Mobeye internet portal 27 6 23 System reset 28 7 Request list of...

Страница 6: ...mperature probes are connected the message will include the indication which probe is in alarm status As soon as the temperature gets back to a value inside the range an SMS text message is sent to th...

Страница 7: ...As default the temperature values are measured and logged every 60 minutes and sent to the portal every 12 hours The log frequency and synchronisation interval can be adjusted The display of the stat...

Страница 8: ...e steps the module will be operational 2 1 INSERT A SIM CARD Open the enclosure by removing the 4 screws and insert a SIM card into the module Push the black cover slightly outward to open the holder...

Страница 9: ...o outside It is possible the bring out only the a part of the head of the sensor or the entire sensor with a part of the cable depending on the application Close the swivel by turning it in order to r...

Страница 10: ...ive ready to receive SMS commands After 3 minutes a time out occurs and the GSM module switches off in order to save the batteries The unit returns to the low power operational mode 2 5 PROGRAM AT LEA...

Страница 11: ...ehind 1111 2 7 SWITCHING ON OFF After the previous steps the Mobeye CML2275 is ready for use and switched on automatically It can be switched on and off by the user defined time schemes or the button...

Страница 12: ...grammed alarm numbers followed by a phone call When you pick up the phone you will hear beeps It is possible to confirm the phone call by answering the phone and pressing any key The other alarm numbe...

Страница 13: ...take over and a power failure message is sent The module continues operating albeit in the low power mode This means the GSM module switches off and only establishes network connection when it needs...

Страница 14: ...nector When using a second input connect this to input 2 As default the inputs are programmed as Normally Open NO contacts This means the inputs are triggered if the input is closed for at least 1 sec...

Страница 15: ...ON example 1111 O1ON To switch off the output send following SMS command to the unit CODE O1OFF example 1111 O1OFF Be aware of the space after 1111 The output has a pulse time of 5 second in the facto...

Страница 16: ...til the LED starts flashing red and green Alternatively the program mode can be accessed by re inserting the batteries First the GSM module establishes network connection During this time the LED flas...

Страница 17: ...text message with the security code and the command 3 The green LED blinks 3 times to indicate the successful configuration In case of an incorrect command the red LED flashes 5 times SMS messages ha...

Страница 18: ...Mobeye Call on off CALL ON OFF ON SMS on off SMS ON OFF ON Input type input 1 TYPEIN1 NO NC NO Input type input 2 TYPEIN2 NO NC NO Delay temperature sensor 1 and 2 DELAYTEMP1 DELAYTEMP2 000 999 min 0...

Страница 19: ...estore TEXT10 20 characters Power restored Power failure delay time DELAYPOW 0 999 min 0 Power message POWERMESSAGE OFF ALERT ALARM ALARM Alarm indication ALARMSOUND ON OFF OFF Pulse time output TO1 0...

Страница 20: ...country code depending on the country leave out the zero for the local area code example 1111 TEL1 447123456789 To delete telephone numbers SMS command delete 1st telephone number DEL1 example 1111 DE...

Страница 21: ...high temperature 1 alarm Temperature 1 too high Text 3 temperature 1 restored Temperature 1 OK Text 4 low temperature 2 alarm Temperature 2 too low Text 5 high temperature 2 alarm Temperature 2 too hi...

Страница 22: ...rature returns to the non alarm status within the delay time no alarm is sent For each temperature input a delay time can be set The time can be set between 0 and 999 minutes As default the temperatur...

Страница 23: ...l be sent Only when the input returned to the non alarm status gets activated again and remains active an alarm will be sent yet after the inactive time If the time is set to 0 minutes the input will...

Страница 24: ...to the programmed telephone numbers followed by a call setting ALARM following the on off settings of CALL and SMS Power restore results in an SMS alert to all numbers This setting can be set to ALER...

Страница 25: ...iren which sounds at an alarm and keeps sounding as long as the unit is in alarm status The siren can be interrupted by briefly pressing the button The alarm indication can be disabled so it won t sou...

Страница 26: ...button It is possible to automatically arm and disarm the unit based on an arming and or disarming time scheme Two schemes can be entered which can be assigned to the days in the week e g to have a d...

Страница 27: ...sday is 2 etc If the scheme is valid for several days the days can be entered in one command e g 12345 means Monday till Friday examples 1111 DAYS1 12345 1111 DAYS2 67 6 20 BUTTONLOCK It can be useful...

Страница 28: ...nd a registration in the Mobeye Internet Portal www mymobeye eu the Mobeye CML2275 offers additional features such as logging of temperature values The logging interval is the interval in which the me...

Страница 29: ...e reinserting the batteries Keep it pressed for about another 5 seconds 3 Release the button immediately after the LED starts to flash 4 If relevant connect the external power supply After a successfu...

Страница 30: ...beye CML2275 can be requested by sending an SMS message with the content without code STATUS REQUEST The status can be requested by sending following SMS text message The status includes the armed dis...

Страница 31: ...requested If the network is weak it is advised to use a SIM card of another network provider or an external GSM antenna a Mobeye accessory The GSM signal strength can be requested by sending following...

Страница 32: ...ower mode Low batteries no external power supply No external power supply batteries need to be replaced External power supply OK batteries OK The external power is restored or the adapter is plugged i...

Страница 33: ...ishes network connection Wait until the network connection is established 2 flashes red every 3 seconds No GSM connection Try the SIM card in any mobile telephone replace SIM card using other telecom...

Страница 34: ...ca 500 mA Dimensions 162 x 82 x 55 mm Ambient temperature 10 C until 50 C Open collector output max 200mA This manual is published by Mobeye All rights the translation included are reserved Any reprod...

Страница 35: ...34...

Страница 36: ......

Отзывы: