Operation & Maintenance, Page
8
of
23
Section
3
– Revision 2.3
End Wear Plates:
m
Thoroughly clean the top of the machine to expose the holes for the lifting eye bolts.
m
Remove the fixings from the end wear plates, which attach the wear plate to the bearing housing. These fixings are
fitted into drilled and tapped holes.
m
Fit lifting eye bolts into the top of the wear plates, and lift out.
m
Thoroughly clean all faces to which the new wear plates fit, to ensure correct seating of the new wear plate. Protect
tapped fixing holes before cleaning.
m
Attach lifting eye bolts to the new wear plate, and lift it into position.
m
Bolt the wear plate into position using the existing set screws.
m
Remove the lifting eyes.
m
Tighten the bolts to the torque rating specified in MMD procedure T056. (Included at the back of this manual).