4.1.3 Fuse Replacement
The Series 943 Controller has a combined fuse holder and power inlet on the rear panel. Replace
the fuse following the steps below.
1.
Unplug the power cord from the power source and the Controller.
2.
Snap out the fuse holder drawer.
3.
Replace the fuse(s) with one of the following time-lag fuses:
• T 0.16 A (Ø 5 mm x 20 mm) - 100 to 120 VAC
• T 0.063 A (Ø 5 mm x 20 mm) - 220 to 240 VAC.
4.
Close and secure the fuse holder drawer.
4.1.4 Accessory Connector
Relay set point contacts, analog output voltage, and high voltage remote disabling can be accessed
from the Accessory port on the rear panel of the Controller. A connector kit to mate to the port is
provided. The figure and chart below identify the pin functions of the Accessory connector.
Do not exceed the rated line voltage of your unit. Electrical
shock may result.
Table 4-1: 15-Pin D-sub Accessory Connector
Pin #
Function
1
Set point relay 1 - normally closed contact
2
Set point relay 1 - common
3
Set point relay 1 - normally open contact
4
Set point relay 2 - normally closed contact
5
Set point relay 2 - common
6
Set point relay 2 - normally open contact
7
not used
8
not used
9
High voltage - disable
10
Ground - high voltage disable
11
Analog output voltage - logarithmic (+)
12
Analog output voltage - logarithmic (-_
13
Analog output voltage - buffered (+)
14
Analog output voltage - buffered (-)
15
not used