937B Controller Instruction Manual
pg. 89
To remove a PROFIBUS Module:
1. Assure that the controller power is OFF, and the power cord is disconnected.
2. Use a #1 Phillips screwdriver to remove the two screws on the top and bottom of the rear
panel of the PROFIBUS module.
3. Use a small, flat-blade screwdriver to gently pry the module away from the rear panel frame until
it slides freely.
4.
Carefully
slide the module out.
5. Place the module on a static-protected workbench.
To install a PROFIBUS module:
1. Assure that the controller power is OFF and the power cord is disconnected.
2. If there is a blanking panel over the COM slot, use a #1 Phillips screwdriver to remove the two
screws on the top and bottom of the blank panel.
3. Align the module to fit and slide freely in the card guides, with the internal 48-pin DIN connector
end first.
4. Gently slide the module forward.
5. Use a #1 Phillips screwdriver to tighten the two screws on the top and bottom of the rear panel of
the module.
RS232/485 serial communication is always available on the 937B controller.
The 9 pin
D-Sub communications connector is located on the back panel of
the AIO/Power module
10.4 Mounting the Controller
The 937B Controller was designed for both rack mounting and bench top use. In both cases, leave at
least 1 inch (25mm) open above the perforated panels to ensure adequate ventilation of the controller.
Side clearance is not required.
To accommodate connectors and cables, leave open about 3 inches (75mm) clearance behind the rear
panel.
Adhesive backed rubber pads are provided for bench top use. Remove the adhesive backing from each
pad and apply one to each corner of the bottom surface.
Optional mounting hardware is available for mounting the 937B Controller in a 19-inch rack.
•
Mounting a single 937B Controller into a 19" rack using MKS half-rack mounting kit
part number 100005651:
1. Attach the faceplate (3.5"x5.5") to each side of the 937B front panel using the four 10-32
screws provided. Secure the screws with the nuts included in the kit.
2. Secure this assembly to the rack using the ¼" screws provided. It may be necessary to
loosen the 10-32 screws securing the faceplates to align the holes with the mounting holes
on the rack.
•
Mounting the 937B Controller with another half-rack instrument using MKS half-rack
mounting kit part number 100007700: