937B Controller Instruction Manual
pg. 81
9.11.3 937B PROFIBUS output buffer map
NOTE: Commands relating to MFCs or flow are not available on the 937B Controller.
OUTPUT Buffer Map
Offset
Size
Format
Description
0
1
Bit field Bit 0 Enable / Clear Set point Relay 1
Bit 1 Enable / Clear Set point Relay 2
Bit 2 Enable / Clear Set point Relay 3
Bit 3 Enable / Clear Set point Relay 4
Bit 4 Enable / Clear Set point Relay 5
Bit 5 Enable / Clear Set point Relay 6
Bit 6 Enable / Clear Set point Relay 7
Bit 7 Enable / Clear Set point Relay 8
1
1
Bit field Bit 0 Enable / Clear Set point Relay 9
Bit 1 Enable / Clear Set point Relay 10
Bit 2 Enable / Clear Set point Relay 11
Bit 3 Enable / Clear Set point Relay 12
Bit 4 N/A
Bit 5 N/A
Bit 6 N/A
Bit 7 N/A
2
1
Bit field Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Power CC/HC/PR Channel A1
Power CC/HC/PR Channel A2
Power CC/HC/PR Channel B1
Power CC/HC/PR Channel B2
Power CC/HC/PR Channel C1
Power CC/HC/PR Channel C2
N/A
N/A
3
1
Bit field Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Set point/Close Mode for MFC on Channel A1
Set point/Close Mode for MFC on Channel A2
Set point/Close Mode for MFC on Channel B1
Set point/Close Mode for MFC on Channel B2
Set point/Close Mode for MFC on Channel C1
Set point/Close Mode for MFC on Channel C2
N/A
PID control enable/disable
4
1
Bit field Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Degas HC Channel A1
Degas HC Channel A2
Degas HC Channel B1
Degas HC Channel B2
Degas HC Channel C1
Degas HC Channel C2
N/A
N/A