BEAM SPOT WASH (3IN1) 380W
BEAM SPOT WASH (3IN1) 380W
Screen Rot
Set the display orientation of the screen
Forward
Don’t reverse display
Reverse
Reverse display
Auto
Automatically detect the direction of the light hanging
light, automatically switch the display direction
DMX
Instruction
Set the indication mode of the DMX signal indicator
Mode 1
Bright when there is a signal, and goes off when there
is no signal
Mode 2
Goes Off when there is a signal, bright when there is
no signal
Mode 3
Flicker when there is a signal, and goes off when
there is no signal
Touch
screen
switch
Select whether to disable the touch screen, when the screen touch
is accidentally damaged, you can disable the touch function and set
the light fixture with the auxiliary input.
Touch
correction
When the screen touch is not accurate, you can enter the
correction page correction screen.
For touch-enabled light, if there is a bad touch, you can enter the calibration page to
re-correct the touch accuracy of the touch screen. Under normal circumstances,
please do not enter this page. If the touch is damaged, select Disable touch switch.
4. Scene editing mode
Enter the page shown in
Figure 1-4
. The light enters the scene editing mode.
Under this page, the light does not receive the DMX controller data, and the
edited data is immediately reflected on the luminaire.
The content of the page is not indented depends on the currently selected
channel, and the displayed channel content and order are consistent with the
light channel table. Through this page, 10 scenes can be edited, as shown in
the following table:
Scene mode
Scene selection
Select the current operation scene
1~10
10 scene change
Scene time
Set the retention time of the current scene when it is
automatic, in units of 0.1 seconds.
0
The current scene does not participate in
automatic scene output
1-255
0.1 second to 25.5 seconds
9
M/Schoose
Effective in non-DMX mode, select the mode of data output, The
light automatically detects the DMX status and automatically
switches the output to prevent data conflicts.
Master
The light runs as built-in
,
If the DMX has no signal, then
output data (synchronized), otherwise no data is output
Slave
The light runs in built-in mode and no output data (not
synchronized with other luminaires)
Auto
If the DMX has no signal, the light operates as built-in.
Otherwise, the light works according to the DMX signal.
Light Switch
(bulb light source) pops up a confirmation dialog box, Select
"SURE" to confirm the current operation, turn the lamp on or off,
and the switch interval is limited to 30 seconds.
OFF
Current lamp output is off
ON
The current light output is already on
Scene mode for single or small fixtures, just output a fixed scene, or need to run a
simple program,can not be
connected to the console, edit it in the scene page.
If the light source is light bulb, after turning off the light bulb, please wait 10 minutes
before turning on the light bulb.
3. Panel display settings
The light support Chinese and English language, upside down display, etc.,
enter the corresponding parameter settings as shown in
Figure 1-3
. The
specific menu contents are as follows:
Display mode
Language
Set the displayed language
English
English display
Chinese
Chinese display
Screen
Saver
Set the screen display content or mode after no operation for 30
seconds
OFF
Keep the last action page, bright screen
Mode 1
Off screen
Mode 2
Black screen, showing the address code of the
current fixture in the lower left corner
Mode 3
Display trademark information, address code and
operation mode
8