IPB-5000A
6. Discription of Display Screens
6-12
⑥
INTERVAL
sets the time period
from the beginning to end of
Envelope waveform.
OFF-SET
sets a plus (+) and
minus (-) allowable value.
Concerning
ON/OFF
,
ON
should
always be selected when using
Envelope function. If OFF is
selected, no Envelope function
works.
After setting the above items,
select
RETURN Button
and
press
ENTER Key
.
⑦
Select
WRITE Button
and press
ENTER Key
to store the setting.
⑧
Here, in this step, Envelope
Waveform
has been set.
When displaying the monitored screen,
Envelope Waveform will appear.
Envelope Waveform