IPB-5000A
9. Time Chart
9-13
(9) Movement of Displacement Sensor
Symbol:
SQ: Squeeze Time
WD: Work Detecting Time (0.4ms Max)
RC: Resistance Pre-check Time
CP : Resistance Judgment Time (1ms)
W1: 1st Weld Time
CO : Cool Time
W2: 2nd Weld Time
HO : Hold Time
a
: Work Detection
When the range of work detection is set to the work detection (
WORK
DETECT
at
6.(8)CONTROL Screen
), the work detection is done after the end
of SQ. If the range of work detection is set to +/-00.00mm, no work detection is
done. Work detection Time is of 0.4ms Max.
b
: 1st Weld Stop (W1)
When
the displacement weld stop (DISPLC) is set to 1st Weld Stop to set the
displacement (
WE1 DINPUT
at
6.(8)CONTROL Screen
) and the displacement
sensor arrives at the set displacement (
e
at the above figure), 1st Weld is
stopped to make the sequence move to the next cool time (CO).
c
: 2nd Weld Stop (W2)
When
the displacement weld stop (DISPLC) is set to 2nd Weld Stop to set
the displacement (
WE1 DINPUT
at
6.(8)CONTROL Screen
) and the
displacement sensor arrives at the set displacement (
f
at the above figure),
2nd Weld is stopped to make the sequence move to the next hold time (HO).
d
: Delay Time
When the value of Delay Time is set to DELAY TIME (
DELAY TIME
at
6.(8)CONTROL Screen
), the displacement (
g
at the above figure) after the
delay time elapses is measured.
Displacement
g
f
e
d
c
b
a
DELAY TIME
HO
SQ
W2
W1
CO
WD
CP
RC
OFF
Weld
Current
Содержание IPB-5000A
Страница 119: ......