IPB-5000A
10. External Communication Function
10-12
5) Reading of Monitored Value (M)
Specified Code
Item
Display (n=0 to 9)
M00
WE1 Monitor Current (PEAK Value) n.nnkA
M01
WE2 Monitor Current (PEAK Value) n.nnkA
M03
WE1 Monitor Voltage (PEAK Value) n.nnV
M04
WE2 Monitor Voltage (PEAK Value) n.nnV
M06
WE1 Monitor Power
nn.nkW
M07
WE2 Monitor Power
nn.nkW
M12
WE1 Monitor Resistance
nn.nm*
(
Note
)
M13
WE2 Monitor Resistance
nn.nm*
M21 Precheck
Monitor
Current
n.nnkA
M30
WE1 Monitor Current (RMS Value)
n.nnkA
M31
WE2 Monitor Current (RMS Value)
n.nnkA
M32
WE1 Monitor Voltage (RMS Value)
n.nnV
M33
WE2 Monitor Voltage (RMS Value)
n.nnV
M65
Work Detecting Displacement
+/-nn.nnnmm
(Note) The symbol “*” means
Ω
.
6) Reading of Items relating with Envelop (V)
Specified
Code
Item
Contents
V00 Envelop
Type
0: Current, 1: Voltage,
2: Power, 3: Resistance
4: Displacement
V01
Interval
Start Time
nnnnnms
V02 Interval
End
Time nnnnnms
V03
Offset
Upper Limit (+)
n.nnkA/n.nnV/nn.nkW/nn.nm*/nn.nnnmm
(
Note
)
V04
Offset
Lower Limit (-)
n.nnkA/n.nnV/nn.nkW/nn.nm*/nn.nnnmm
(
Note
)
V05 Envelop
ON/OFF
0
:
OFF, 1
:
ON
(Note) The symbol “*” means
Ω
.
7) Setting of Items relating with Counter (C)
Specified
Code
Item
Contents
C00
Reading of
Displayed Counter
C14 Counter
Mode
0: TOTAL, 1: GOOD,
2: WORK
C05 Preset
(TOTAL/GOOD)
C06 Preset
(WORK)
C07 Preset
(WELD)
C11
Counter Reset (All Counters)
Содержание IPB-5000A
Страница 119: ......