IPB-5000A
10. External Communication Function
10-10
③
Specified Code
1) Specifying of Weld Sequence (T)
Dimension of “ms” is added to each data.
Specified
Code
Item
Range of
Setting
Increment/
Decrement
T01 Squeeze Time
0000ms to 999ms
1ms
T02 Upslope 1 Time
000.0ms to 100.0ms
0.2ms
T03 1st.
Weld
Time
000.0ms
to
100.0ms 0.2ms
T04 Downslope 1 Time
000.0ms to 100.0ms
0.2ms
T05 Cool
Time
00.0ms
to
99.8ms 0.2ms
T06 Upslope 2 Time
000.0ms to 100.0ms
0.2ms
T07
2nd. Weld Time
000.0ms to 100.0ms
0.2ms
T08 Downslope 2 Time
000.0ms to 100.0ms
0.2ms
T13 Hold
Time
000ms
to
999ms 1ms
T15 Precheck
Weld
Time 00.0ms
to
10.0ms 0.2ms
2) Setting of Control Current, Voltage and Power (H)
Specified
Code
Item
Range of
Setting
Increment/
Decrement
H01
WE1 Current Setting
0.20kA to 6.00kA
0.01kA
H02
WE2 Current Setting
0.20kA to 6.00kA
0.01kA
H04
WE1 Voltage Setting
0.50V to 9.99V
0.01V
H05
WE2 Voltage Setting
0.50V to 9.99V
0.01V
H06 WE1
Power
Setting 00.2kW
to 20.0kW
0.1kW
H07 WE2
Power
Setting 00.2kW
to
20.0kW 0.1kW
H21
Precheck Voltage Setting 0.00V to 9.99V
0.01V
3) Setting of Monitor Upper/Lower Limit (N)
Specified
Code
Item
Range of Setting
Increment/
Decrement
N00
WE1 Monitor Current Upper Limit
0.00kA to 9.99kA 0.01kA
N01
WE1 Monitor Current Lower Limit
0.00kA to 9.99kA 0.01kA
N02
WE2 Monitor Current Upper Limit
0.00kA to 9.99kA 0.01kA
N03
WE2 Monitor Current Lower Limit
0.00kA to 9.99kA 0.01kA
N06
WE1 Monitor Voltage Upper Limit
0.00V to 9.99V
0.01V
N07
WE1 Monitor Voltage Lower Limit
0.00V to 9.99V
0.01V
(Continued)
Содержание IPB-5000A
Страница 119: ......