13
Installation: electrical
Indirect wiring
Mixergy indirect cylinders can be wired into both S-plan and
Y-plan heating configurations. Please use the following instruc-
tions for reference.
These instructions are only for the wiring of the cylin-
der and cannot be used as a reference for a complete
central heating system.
Indirect and external controller wiring
Indirect cylinders are wired via the indirect junction box. The lo-
cation of this box is given in the schematic on page 8. Please
use the diagrams on page 14 for reference. Full schematics are
Wiring with 2 port zone valve (S-plan)
• Connect a 5A fused supply (
L
) to the indirect junction box ter-
minal labelled ‘N’.
• Connect earth to the indirect junction box terminal labelled
GND.
• Connect the 2 port valve brown (
Br
) cable to the indirect junc-
tion box terminal labelled ‘L1’.
Wiring with 3 port mid position valve and 2 port zone valve
(Y-plan)
• Connect a 5A fused supply (
L
) to the indirect junction box ter-
minal labelled ‘N’.
• Connect earth to the indirect junction box terminal labelled
GND.
• Connect the 2 port valve brown (
Br
) cable to the indirect junc-
tion box terminal labelled ‘L1’.
• Connect the 3 port valve grey (
Gr
) cable to the indirect junction
box terminal labelled ‘L2’
• Connect the 3 port valve orange cable to the 2 port valve or-
ange cable.