Press [BANK] to select the BANK number that you want to set.

 

»

The BANK indicator corresponding to the selected BANK number will light.

Tips

Select a BANK number from BANK1 through 3. Tolerance values cannot be set if 

BANK0 is selected.

Press [Fn].

 

»

The BANK indicator will light in amber. (Tolerance value S1 will be selected.)

Tips

Tolerance values are set in the order S1, S2, S3, S4. The Tolerance judgment 

indicator displays as shown in the following table. (The tolerance value to be set 

will be selected.)

Tolerance value

BANK indicator

S1

Amber indicator on

S2

Amber indicator blinks

S3

Red indicator blinks

S4

Red indicator on

Set the tolerance values using the same procedure as for setting 
the 3-step tolerance values.

 

»

The values will be applied in the order S1, S2, S3, S4, and then the Counter will 

return to the Counter display.

Tips

• 

For details about setting the 3-step tolerance values, see 

"3-step tolerance 

value setting (3-step tolerance zone selection)" (page 5).

• 

An error will occur unless S1 < S2 < S3 < S4 or S1 = S2 = S3 = S4.

4.5 

Optional Constant Value Setting

You can set an arbitrary multiplication factor for the counter value. If this 

function is used, the accuracy cannot be guaranteed.

Tips

• 

Set the value of parameter number 16 to 3 (arbitrary value) in advance.

• 

When an arbitrary constant is set, the decimal point will blink.

This section explains how to set an arbitrary multiplication factor.

Press and hold [Fn], and then press [P.SET].

 

» The Counter enters Parameter mode. 

(The set value of parameter number 00 

will blink.)

Parameter number

Set value

Press [P.SET] twice to set the value to 2.

 

» The display appears as to the right.

Parameter number

Set value

Press [Fn].

 

» The previous multiplication factor will 

be displayed. (The example on the right 

shows the previous value as 1.0000.)

Press [MODE].

 

» The input digit will shift to the right. (The 

currently selected digit will blink.)

Press [P.SET].

 

»

The multiplication factor will be modified.

Repeat step 

4

 and step 

5

 until the least significant digit has 

been set.

 

»

The least significant digit will blink.

Tips

The setting range is ±9.9999.

Press [MODE].

 

» The multiplication factor will be applied. 

(The least significant digit stops 

blinking.)

Press and hold [Fn], and then press [P.SET].

 

» The Counter will return to the Counter display.

External Input/Output Function

This product has an I/O connector that enables data communication with 

external equipment. There are 2 types of external output modes: "Tolerance 

judgment output mode", which outputs the tolerance judgment result, and "BCD 

output mode", which outputs the counter data with BCD. Also, you can activate 

the Preset function and activate HOLD on the counter value through external 

signal input.

5.1 

Connections

 

„

Compatible plug and connecting cable

Compatible plug:

 

y

Option No. 02ADB440 (plug and cover set)

 

y

Commercial plug 10136-3000PE (3M), cover 10336-52A0-008 (3M)

 

y

Commercial plug DX40M-36P (HIROSE), cover DX30M-36-CV (HIROSE)

Cable: Use shielded wires and limit the connecting cable length to 3 m or less.

 

„

Pin assignment

Tips

•  External input is valid when input voltage is "L". (External input is negative logic.)
• 

"I/O" in the following table refers to the first letters of "Input/Output" respectively. 

Refer to the input circuit for "I", and the output circuit for "O".

• 

In BCD output mode, it is possible to invert the output logic of pin numbers 3 

through 26 and pin number 31 by setting parameter number 24 (BCD output logic).

 

z

Tolerance judgment output mode

Pin 

number

I/O

Name

Functions

1, 2

-

COM

Internally connected to GND

3

O

L1

Tolerance judgment result output

 

y

Relevant output terminal: "L"

 

y

Output on error: both L1 and L5 are "L"

4

O

L2

5

O

L3

6

O

L4

7

O

L5

10

O

NOM

Normal output
Normal: "L"

27

I

SET1

Setting BANK, Peak mode:
Input the set value with SET in advance, then 

assign with MODE, BANK.

28

I

SET2

29

I

MODE

Switching Peak:
Input in combination with SET.

34

I

HOLD

HOLD input

35

I

P.SET

Normal measurement: Preset
Peak mode measurement: Peak clear

36

I

BANK

Switching BANK:

Input in combination with SET.

-

-

NC

No connection should be made other than 

those shown above.

 

z

BCD output mode

Pin  

number

I/O

Name

Pin  

number

I/O

Name

Pin  

number

I/O

Name

1

-

COM

13

O

4 ×

 10

 2

25

O

4 ×

 10

 5

2

-

COM

14

O

×

 10

 2

26

O

×

 10

 5

3

O

×

 10

 0

15

O

×

 10

 3

27

I

SET1

4

O

×

 10

 0

16

O

×

 10

 3

28

I

SET2

5

O

4 ×

 10

 0

17

O

4 ×

 10

 3

29

I

MODE

6

O

×

 10

 0

18

O

×

 10

 3

30

-

NC

7

O

×

 10

 1

19

O

×

 10

 4

31

O

SGN

8

O

×

 10

 1

20

O

×

 10

 4

32

O

NOM*

1

9

O

4 ×

 10

 1

21

O

4 ×

 10

 4

33

O

READY*

2

10

O

×

 10

 1

22

O

×

 10

 4

34

I

HOLD*

1

11

O

×

 10

 2

23

O

×

 10

 5

35

I

PSET*

1

12

O

×

 10

 2

24

O

×

 10

 5

36

I

INH*

3

1

19

18

36

Содержание EG-101P

Страница 1: ...nted Precautions for Use Do not remove the cover or disassemble the product Otherwise you may be subject to electric shock and there is a risk of breakage or fire due to a short circuit caused by meta...

Страница 2: ...ear Gage OUTPUT connector I O connector For connecting an I O connecting cable Grounding terminal For connecting a grounding wire Power terminal block For connecting the Terminal strip connecting cabl...

Страница 3: ...number to 12 The current value of parameter number 12 will blink Parameter number 12 sets the resolution Parameter number Set value 5 Repeatedly press P SET to set the set value to 1 resolution 5 m T...

Страница 4: ...p For EG 101P this is not available 0 Disabled 1 Enabled Parameter number Setting item Description the values in bold indicate the default value 43 Origin initialization when the power is turned on EG...

Страница 5: ...tolerance judgment function is disabled when BANK0 is selected 4 4 Tolerance Value Setting There are 2 settings for the tolerance value 3 step and 5 step Tips Set the value of parameter number 21 to...

Страница 6: ...st significant digit stops blinking 8 Press and hold Fn and then press P SET The Counter will return to the Counter display 5 External Input Output Function This product has an I O connector that enab...

Страница 7: ...e BANK specification MODE BANK SET1 2 3 Min 10 ms Min 10 ms Min 5 ms Max 10 ms DATA BANK pin number 36 BANK switchover MODE pin number 29 Peak switchover SET2 SET1 BANK0 H H BANK1 H L BANK2 L H BANK3...

Страница 8: ...the origin Automatic cancellation Err 90 L Counter value status Tolerance value setting error Input the tolerance value again Press P SET Err 95 L Counter value status Key protect Cancel the key prot...

Отзывы: