2

1.2.  Before installation (relocation)

 Caution:

•  Be extremely careful when transporting the units. Two or more persons are 

needed to handle the unit, as it weighs 20 kg [44 lbs] or more. Do not grasp the 
packaging bands. Wear protective gloves to remove the unit from the packaging 
and to move it, as you can injure your hands on the fins or other parts.

•  Be sure to safely dispose of the packaging materials. Packaging materials, such 

as nails and other metal or wooden parts may cause stabs or other injuries.

•  The base and attachments of the outdoor unit must be periodically checked 

 Warning:

•  The unit must not be installed by the user. Ask a dealer or an authorized 

technician to install the unit. If the unit is installed incorrectly, water leakage, 
electric shock, or fire may result.

•  For installation work, follow the instructions in the Installation Manual and use 

tools and pipe components specifically made for use with R410A refrigerant. 
The R410A refrigerant in the HFC system is pressurized 1.6 times the pressure 
of usual refrigerants. If pipe components not designed for R410A refrigerant are 
used and the unit is not installed correctly, the pipes may burst and cause dam-
age or injuries. In addition, water leakage, electric shock, or fire may result.

•  The unit must be installed according to the instructions in order to minimize 

the risk of damage from earthquakes, typhoons, or strong winds. An incor-
rectly installed unit may fall down and cause damage or injuries.

•  The unit must be securely installed on a structure that can sustain its weight. 

If the unit is mounted on an unstable structure, it may fall down and cause 
damage or injuries.

•  If the air conditioner is installed in a small room, measures must be taken to 

prevent the refrigerant concentration in the room from exceeding the safety 
limit in the event of refrigerant leakage. Consult a dealer regarding the appro-
priate measures to prevent the allowable concentration from being exceeded. 
Should the refrigerant leak and cause the concentration limit to be exceeded, 
hazards due to lack of oxygen in the room may result.

•  Ventilate the room if refrigerant leaks during operation. If refrigerant comes 

into contact with a flame, poisonous gases will be released.

•  All electric work must be performed by a qualified technician according to 

local regulations and the instructions given in this manual. The units must be 
powered by dedicated power lines and the correct voltage and circuit breakers 
must be used. Power lines with insufficient capacity or incorrect electrical 
work may result in electric shock or fire.

•  Use C1220 copper phosphorus, for copper and copper alloy seamless pipes, 

to connect the refrigerant pipes. If the pipes are not connected correctly, the 
unit will not be properly grounded and electric shock may result.

•  Use only specified cables for wiring. The wiring connections must be made 

securely with no tension applied on the terminal connections. Also, never 
splice the cables for wiring (unless otherwise indicated in this document). 
Failure to observe these instructions may result in overheating or a fire.

•  The terminal block cover panel of the outdoor unit must be firmly attached. If 

the cover panel is mounted incorrectly and dust and moisture enter the unit, 
electric shock or fire may result.

•  When installing or relocating, or servicing the air conditioner, use only the 

specified refrigerant (R410A) to charge the refrigerant lines. Do not mix it with 
any other refrigerant and do not allow air to remain in the lines.

  If air is mixed with the refrigerant, then it can be the cause of abnormal high 

pressure in the refrigerant line, and may result in an explosion and other 
hazards.

  The use of any refrigerant other than that specified for the system will cause 

mechanical failure or system malfunction or unit breakdown. In the worst 
case, this could lead to a serious impediment to securing product safety.

•  Use only accessories authorized by Mitsubishi Electric and ask a dealer or an 

authorized technician to install them. If accessories are incorrectly installed, 
water leakage, electric shock, or fire may result.

•  Do not alter the unit. Consult a dealer for repairs. If alterations or repairs are 

not performed correctly, water leakage, electric shock, or fire may result.

•  The user should never attempt to repair the unit or transfer it to another loca-

tion. If the unit is installed incorrectly, water leakage, electric shock, or fire 
may result. If the air conditioner must be repaired or moved, ask a dealer or 
an authorized technician.

•  After installation has been completed, check for refrigerant leaks. If refriger-

ant leaks into the room and comes into contact with the flame of a heater or 
portable cooking range, poisonous gases will be released.

1.1. Before installation

 Caution:

•  Do not use the unit in an unusual environment. If the air conditioner is installed 

in areas exposed to steam, volatile oil (including machine oil), or sulfuric gas, 
areas exposed to high salt content such as the seaside, or areas where the 
unit will be covered by snow, the performance can be significantly reduced 
and the internal parts can be damaged.

•  Do not install the unit where combustible gases may leak, be produced, flow, 

or accumulate. If combustible gas accumulates around the unit, fire or explo-
sion may result.

•  The outdoor unit produces condensation during the heating operation. Make 

sure to provide drainage around the outdoor unit if such condensation is likely 
to cause damage.

•  When installing the unit in a hospital or communications office, be prepared for 

noise and electronic interference. Inverters, home appliances, high-frequency 
medical equipment, and radio communications equipment can cause the air 
conditioner to malfunction or breakdown. The air conditioner may also affect 
medical equipment, disturbing medical care, and communications equipment, 
harming the screen display quality.

for looseness, cracks or other damage. If such defects are left uncorrected, 
the unit may fall down and cause damage or injuries.

•  Do not clean the air conditioner unit with water. Electric shock may result.
•  Tighten all flare nuts to specification using a torque wrench. If tightened too 

much, the flare nut can break after an extended period and refrigerant can 
leak out.

Contents

1. Safety 

precautions 

..................................................................................... 2

2. Installation 

location 

.................................................................................... 3

3.  Installing the outdoor unit .......................................................................... 5
4.  Installing the refrigerant piping .................................................................. 5

5.  Drainage piping work ................................................................................. 8
6. Electrical 

work 

........................................................................................... 8

7. Test 

run 

.................................................................................................... 11

1. Safety precautions

  Before installing the unit, make sure you read all the “Safety precau-

tions”.

  Please report to or take consent by the supply authority before con-

nection to the system.

 Warning:

Describes precautions that must be observed to prevent danger of injury or 
death to the user.

 Caution:

Describes precautions that must be observed to prevent damage to the unit.

After installation work has been completed, explain the “Safety Precautions”, use, and 
maintenance of the unit to the customer according to the information in the Operation 
Manual and perform the test run to ensure normal operation. Both the Installation 
Manual and Operation Manual must be given to the user for keeping. These manuals 
must be passed on to subsequent users.

 : Indicates a part which must be grounded.

 Warning:

Carefully read the labels affixed to the main unit.

Confirmation of parts attached

In addition to this manual, the following parts are supplied with the outdoor unit.
They are used for grounding the S terminals of transmission terminal blocks TB3, 
TB7. For details refer to “6. Electrical work”.

Grounding lead wire (

×

 2)

Содержание PUMY-P NHMU

Страница 1: ...MANUAL DE INSTALACI N Para un uso correcto y seguro lea detalladamente este manual y el manual de instalaci n de la unidad interior antes de instalar la unidad de aire acondicionado PARA EL INSTALADO...

Страница 2: ...ards The use of any refrigerant other than that speci ed for the system will cause mechanical failure or system malfunction or unit breakdown In the worst case this could lead to a serious impediment...

Страница 3: ...ure enters the refriger ant lines refrigeration oil deterioration may result Do not use a charging cylinder If a charging cylinder is used the composition of the refrigerant will change and the ef cie...

Страница 4: ...outlet guides for upward air ow 2 4 2 When installing multiple outdoor units Leave 10 mm 13 32 inch space or more between the units 1 Obstacles at rear only Fig 2 8 2 Obstacles at rear and above only...

Страница 5: ...d cause damage or injuries The unit must be installed according to the instructions in order to minimize the risk of damage from earthquakes typhoons or strong winds An incor rectly installed unit may...

Страница 6: ...ze adjustment gauge can be used to con rm A measurements Warning When installing the unit securely connect the refrigerant pipes before start ing the compressor A Liquid pipe Gas pipe PUMY 9 52 3 8 15...

Страница 7: ...lant to seal the ends of the thermal insulation around the pipe connection sections to prevent water from entering the thermal insulation Note Triple Evacuation Evacuate the system to 4 000 microns fr...

Страница 8: ...nsmission lines of different systems are wired with the same multiplecore cable the resultant poor transmit ting and receiving will cause erroneous operations 6 Electrical work 7 Only the transmission...

Страница 9: ...e same group to the terminal block on the remote controller RC d Connect together terminals M1 M2 and terminal S on the terminal block for central control TB7 for the outdoor unit OC e The jumper conn...

Страница 10: ...hat generated overcurrent may include some amount of direct current Caution Some installation site may require attachment of an earth leakage breaker If no earth leakage breaker is installed it may ca...

Страница 11: ...er carry out pump down operation if the amount of refrigerant inside the indoor unit is larger than the amount of charge less refrigerant Carrying out a pump down operation when the amount of refriger...

Страница 12: ...rminales Asimismo no empalme nunca los cables al realizar el cableado a menos que se indique lo contrario en este documento El hecho de no seguir estas instrucciones puede provocar un sobrecalenta mie...

Страница 13: ...gua de postes de iluminaci n o de tel fono Si la unidad no est bien conectada a la l nea de tierra se puede producir una descarga el ctrica Utilice disyuntores interruptor de falta de tierra interrupt...

Страница 14: ...unidades correlativas Adem s se debe dejar el espacio indicado No utilice las gu as para salida de aire opcionales para corriente de aire hacia arriba 3 Obst culos s lo en la parte delantera Fig 2 10...

Страница 15: ...otros peligros Usar un refrigerante distinto al indicado para el sistema provocar un fallo mec nico un funcionamiento defectuoso del sistema o la aver a de la unidad En el peor de los casos podr a sup...

Страница 16: ...gerante R410A Para con rmar las medidas de A se puede utilizar el ajustador del tama o Atenci n Al instalar la unidad conecte rmemente las tuber as de refrigerante antes de poner en marcha el compreso...

Страница 17: ...s ya que funcionan como selladoras para evitar fugas de refrigerante 5 Utilice un sellador para proteger las conexiones de los tubos y los extremos del material aislante no se impregnen de agua Nota V...

Страница 18: ...las l neas de transmisi n de sistemas diferentes est n conectados con los mismos cables de varias almas la pobre transmisi n y recepci n resultante dar lugar a funciones err neas 6 Trabajo el ctrico 7...

Страница 19: ...itud de esta secci n L8 deber a incluirse en longitud m xima de c lculo y la longitud total 2 Controlador remoto MA Longitud mayor a trav s de las unidades exteriores Cable M NET L1 L2 L3 L4 y L1 L2 L...

Страница 20: ...iesgo de que se produzca calentamiento o un incendio Aseg rese de escoger un interruptor de protecci n de sobrecarga adecuado No olvide que la sobrecorriente generada puede contener peque as cantidade...

Страница 21: ...r y vuelva a colocar el tap n a cada v lvula de parada Notas 1 Nunca realice el vaciado si la cantidad de refrigerante del interior de la unidad interior es superior a la cantidad de refrigerante no c...

Страница 22: ...nt sans tension sur les bornes Ne jamais effectuer de jonction sur les c bles sauf en cas d indications contraires Le non respect de cette consigne peut entra ner une surchauffe ou un incendie Le couv...

Страница 23: ...te de l appareil peut provoquer un choc lectrique Utiliser des coupe circuits disjoncteur de fuite la terre interrupteur d isolement fusible B et disjoncteur bo tier moul la capacit sp ci e Si la capa...

Страница 24: ...pacer galement les appareils comme illustr Ne pas utiliser les guidages de sortie d air en option pour un d bit d air vers le haut 3 Obstacles uniquement l avant Fig 2 10 Lors de l utilisation d un gu...

Страница 25: ...frig rant diff rent de celui sp ci pour le climatiseur peut en tra ner des d faillances m caniques des dysfonctionnements du syst me ou une panne de l appareil Dans le pire des cas cela peut entra ne...

Страница 26: ...au tableau 1 pour l vasement des tuyaux de r frig rant R410A La jauge de r glage de la taille peut tre utilis e pour con rmer les mesures A Avertissement Pendant l installation de l appareil brancher...

Страница 27: ...de l isolation thermique autour des sections de raccordement des tuyaux a n d emp cher l eau de p n trer dans l isolation thermique Remarque Triple vacuation vacuez le syst me de 4 000 microns par le...

Страница 28: ...ts syst mes devaient tre reli es par le m me c ble ls multiples la transmission et la r ception seraient mauvaises ce qui conduirait un fonctionnement erron des appareils 6 Installations lectriques 7...

Страница 29: ...IC qui poss de l adresse la plus r cente au sein d un m me groupe au bloc terminal de la commande distance RC d Connecter les bornes M1 M2 et S des blocs terminaux TB7 pour le contr le central sur les...

Страница 30: ...ous d utiliser le correct interrupteur de protection contre la surintensit de courant Veuillez noter que la surintensit de courant g n r e peut comprendre une certaine quantit de courant direct Pr cau...

Страница 31: ...rr t Remarque 1 Ne jamais proc der au pompage si la quantit de r frig rant dans l appareil int rieur est sup rieure la quantit de r frig rant sans charge suppl mentaire Le pompage lorsque la quantit d...

Страница 32: ...on this manual before handing it to the customer This product is designed and intended for use in the residential commercial and light industrial environment HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CH...

Отзывы: