7. APPLICATION INSTRUCTIONS
7
−
146
MELSEC-A
Operation Errors
In the following cases, an operation error occurs and the DSFLP instruction is not
executed.
(1) Set value of (D) is other than 1 to 8.
(2) Set value of "n" is other than 0 TO 4.
(When set value of "n" is 2 to 4, see section 7.11.3)
(3) Index qualification is used for specification of (D) and "n".
Minor Errors
In the following cases, the minor error (control change error) occurs and present
position data change or speed change is not executed. The error detection flag
(Xn7) is set and the error code is stored in the minor error code areas which
correspond to the troubled axis.
(1) For present position data change, the axis specified with (D) has started.
(2) For speed change, the axis specified with (D) is executing zero return or circular
interpolation.
(3) For speed change, the axis specified with (D) is decelerating.
(4) For speed change, the speed specified with "n" is out of the range from 1 to the
speed limit value.