7. APPLICATION INSTRUCTIONS
7
−
95
MELSEC-A
Execution Conditions
Operation Errors
In the following cases, operation error occurs and the error flag turns on.
•
The station number specified at "n1" is not a local station.
•
"n2" points starting at (D) exceed the specified device range.
•
Specification of "n2" is other than 1 to 32.
POINT
If an LWTP instruction is executed by a CPU which is not for data link, or when
the mode select switch for the link card is set for OFFLINE, no operation error
occurs and M9202 (LWTP instruction enable flag) is set without the LWTP
instruction processing.
Write command
Executed only once
LWTP
ON
OFF