[INSTALLATION PRECAUTIONS] 

CAUTION 

z

 Use the programmable controller in an environment that conforms to the 

general specifications in CPU module user's manual. 
Using the programmable controller in the environments outside the ranges 
stated in the general specifications will cause electric shock, fire, 
malfunction, or damage to/deterioration of the product. 

z

 Do not touch conductive parts or electronic components of the module with 

your bare hands. 
This could cause malfunction or failure of the module 

z

 Insert the module fixing projection into the fixing hole in the base unit and 

then tighten the module mounting screw within the specified torque. Then 
tighten the module mounting screw to the specified torque. Incorrect 
installation with no screws could result in malfunction, failure or fall of the 
module. Tightening the screw excessively may cause fall, short circuit, or 
malfunction of the module due to damage of the screw or the module. 

z

 Always shut off all phases of the programmable controller power supply 

and AS-i power supply externally before mounting or removing the module. 
Failure to shut off all phases could lead to product damage. 

[WIRING PRECAUTIONS] 

WARNING 

z

 Switch off all phases of the programmable controller power supply and AS-i 

power supply outside the programmable controller before starting installing 
or wiring work. There is a risk of electric shock or malfunction. 

z

 Always install the terminal covers enclosed with the product before turning 

ON the power or operating the product after installation or wiring. 
Failure to install the terminal cover could lead to electric shocks. 

 

 

Содержание MELSEC-A A1SJ71AS92

Страница 1: ...ubishi general purpose programmable controller MELSEC A Series Prior to use please read both this manual and detailed manual thoroughly and familiarize yourself with the product MODEL A1SJ71AS92 U H J...

Страница 2: ...e safety precautions are classified into two levels WARNING and CAUTION Indicates that incorrect handling may cause hazardous conditions resulting in death or severe injury Indicates that incorrect ha...

Страница 3: ...OK X4 X9 Using the above information configure an interlock circuit on the sequence program so that the system activates safely There is a risk of accidents caused by incorrect outputs or incorrect o...

Страница 4: ...ied torque Incorrect installation with no screws could result in malfunction failure or fall of the module Tightening the screw excessively may cause fall short circuit or malfunction of the module du...

Страница 5: ...nected to a module must always be run in a duct or held securely using clamps If a cable is not run in a duct or not held securely using clamps the cable will sag move or be pulled by mistake which wi...

Страница 6: ...of the PRODUCT in y Nuclear Power Plants and any other power plants operated by Power companies and or any other cases in which the public could be affected if any problem or fault occurs in the PROD...

Страница 7: ...RECAUTIONS Correspondence to EMC Directives and Low Voltage Directives Chapter 3 4 6 Addition CONDITIONS OF USE FOR THE PRODUCT Dec 2011 IB NA 0800122 D Addition SAFETY PRECAUTIONS Chinese This manual...

Страница 8: ...view 1 2 Performance Specifications 2 3 Handing 3 3 1 Precautions for Handling 3 4 Part Identification Nomenclature 4 5 Wiring 5 5 1 Precautions for Wiring 5 5 2 Wiring 5 6 Outline Dimension Drawings...

Страница 9: ...itsubishi programmable controllers maintain EMC and Low Voltage Directives when incorporated into other machinery or equipment certain measures may be necessary Please refer to one of the following ma...

Страница 10: ...e A1SJ71AS92 are indicated on the following chart Use Application The master of AS i system Main base Extension base I O slot 2 Please verify the existence of the following parts after opening the pac...

Страница 11: ...independent for each system Star line tree or ring Communication method APM modulation method Alternating Pulse Modulation Error control method Parity check Internal memory Flash ROM for registering...

Страница 12: ...ed wiring board from the case It may damage the module 3 Tighten the module mounting screws terminal block installation screws and terminal block terminal screws within the following range Screw posit...

Страница 13: ...witch is used to change between the protected operation mode and configuration mode RUN This turns ON when the A1SJ71AS92 is running normally U ASI The AS i circuit is sufficiently powered This LED re...

Страница 14: ...5 2 Wiring Use an AS i cable to connect the A1SJ71AS92 to the AS i system An example of wiring to the A1SJ71AS92 is shown below Confirm each module being used for the AS i power supply and slave term...

Страница 15: ...6 6 Outline Dimension Drawings 6 1 A1SJ71AS92 Unit mm...

Страница 16: ...7 MEMO...

Страница 17: ...8 MEMO...

Страница 18: ...not to be the cause of Mitsubishi machine damage or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mi...

Отзывы: