- 7 -
CAUTION:
BEFORE ATTEMPTING TO REMOVE OR
REPAIR ANY PCB, UNPLUG THE POWER
CORD FROM THE A.C. SOURCE.
LOCATION OF PRINTED CIRCUIT
BOARDS
Note :
• Take caution when removing flat cables to prevent any
contact problem.
• Connect and disconnect the flat cables at right angles to
the connector and make sure that it is completely
secured.
• After servicing the PCB, restore the flat cable and leads
to their former state.
PCB-OPE
PCB-MAIN
HOW TO EXECUTE CIRCUIT BOARD SERVICE
Fig. 6
a
PCB - OPE
Connector OS
Fig. 7
1. PCB-OPE
1. Remove the Top Cover.
(Refer to Para. 1 of the DISASSEMBLY.)
2. Remove the Front Panel.
(Refer to Para. 2 of the DISASSEMBLY.)
3. Unfasten the fastening screw (
a
) and remove the PCB-
OPE as shown in Fig. 7.