FX-10GM POSITIONING CONTROLLER
2-6
SPECIFICATIONS 2
2.5
Optional Units
When an I/O connector of the positioning unit is connected to a terminal block, the
following cables are convenient.
Optional cables
The following optional cables are available to connect the positioning unit.
16-points
16-points
FX-16E-150CAB type cable (1.5m)
FX-16E-300CAB type cable (3.0m)
FX-16E-500CAB type cable (5.0m)
FX-16E-150CAB-R type cable (1.5m)
FX-16E-300CAB-R type cable (3.0m)
FX-16E-500CAB-R type cable (5.0m)
FX-16E-500CAB-S type cable (5.0m)
FX-10GM
CON1
FX(E-20GM)
CON1
CON2
Positioning unit
Terminal block
Flat cable with
connector at both
ends.
Round multi-cored
cable with connector
at both ends.
Connector Separate wires
at one end.
If no terminal
block is used,
the cable can
be cut off at
one end.
Applicable connectors
The specifications for connector cables made by the user and for the connectors
to be used when connecting additional equipment are indicated below.
1) When making a cable
①
Flat cables
Wire size:
AWG28 (0.1 mm
2
)
1.27 pitch, 20 cores
Example of pressure displacement con-
nectors (female)
•
HIF3BA-20D-2.54R
Hirose Denki
•
FRC5-A020-3TOS
Daiichi Denshi
•
FRC2-A020-30S
Daiichi Denshi
②
Separate wires
Wire size: AWG22 to 20 (0.3 to 0.5 mm
2
)
Solderless contacts: HU-411S (0.3 mm
2
)
Daiichi Denshi
HU-411SA (0.5 mm
2
)
Daiichi Denshi
Housing: HU-200S2-001
Daiichi Denshi
*
Depending on the variation in sheath
thickness, it may be difficult to accom-
modate the wires in the housing.
UL-1061 wires are recommended.
2) When connecting additional equipment
The destination side connectors to which
M i t s u b i s h i ' s o p t i o n a l c a b l e s c a n b e
connected include the following models.
•
HIF3BA-20PA-2.54DSA Hirose Denki
•
FRC5-C20S53T-OL
Daiichi Denshi
•
FRC2-C20S13-OL
Daiichi Denshi
The internal connectors of the positioning
unit and extension blocks are equivalent to
the models indicated above.