background image

INTRODUCTION   1

1-3

FX-10GM POSITIONING CONTROLLER

1.2.2

System configuration

This section explains the system configuration and I/O assignment of the FX-10GM.

Independent operation

The FX-10GM can operate independently because it is equipped with a power
supply of 24V DC, CPU, operation inputs, mechanical inputs and drive unit inputs/
outputs as described on the next page.

The FX-10GM can be connected to external I/O devices because it is equipped
with 4 input points (X0 to X3) and 6 output points (Y0 to Y5) as general purpose
I/Os.  When the I/O points are insufficient, use a programmable controller as
described below.

Connecting a programmable controller

Applicable programmable controller: FX or FX

2C

 Series

The FX-10GM is treated as a special unit of the programmable controller.  Eight
special units (such as the analog I/O unit, the high-speed counter, etc.) including
the FX-10GM can be connected to a programmable controller.

POWER
RUN
BATT.V

PROG-E
CPU-E

‚`‚b‚W‚T `‚Q‚U‚S‚u

L

N

24+

X1

X3

X5

X7

COM X0

X2

X4

X6

X10

X11

X12

X13

X14

X15

X16

X17

RUN

SG

Y0

Y2

Y4

Y6

Y10

Y12

Y14

Y16

COM1 Y1

Y3

COM2 Y5

Y7

COM3 Y11 Y13

COM4 Y15

Y17

PULL

24

+

24

-

C

O

M

1

M

A

N

U

B

POWER

3

7

0

4

1

5

2

6

3

7

0

4

1

5

2

6

A

POWER

3

7

0

4

1

5

2

6

3

7

0

4

1

5

2

6

TRANSISTOR BLOCK

A

B

24

+

24

-

C

O

M

1

M

A

N

U

1

0

1

2

3

COM

COM

4

5

6

7

COM

COM

1

0

1

2

3

COM

COM

4

5

6

7

COM

COM

24+

24-

Terminal block

Input unit described 

on the next page

Special

units No.1

Special

units No.0

Programmable controller

Output unit described 

on the next page

X00    X17        (X00    X03)  X20    X27               (X00    X03)

Y00    Y17       (Y00    Y05)                Y20    Y37  (Y00    Y05)

Peripheral units for the FX-10GM

E-20TP teaching panel

FX-PCS-KIT-GM-EE software kit for personal computer

Peripheral units for the programmable controller

Various programming tools

Data access unit

I/O assignment
The FX-10GM is treated as a special unit of the programmable controller.  The
special unit Nos. 0 to 7 are automatically assigned to each of the special units
from the unit closest to the programmable controller (The No. assigned here is
regarded as the unit No. specified in the FROM/TO instruction.)
No I/Os of the programmable controller are assigned, and the general purpose I/
Os of the FX-10GM are controlled by the 10GM.

Note

For details of the I/O assignment in the programmable controller, refer to the FX SERIES
HARDWARE MANUAL.  The number of extension blocks connected after the 10GM
is limited.  See section 2.2.2.

Содержание FX-10GM

Страница 1: ...RAMMING MANUAL and FX SERIES HARDWARE MANUAL Before attempting to install or use the FX 10GM unit this manual and FX 10GM FX E 20GM HARDWARE PROGRAMMING MANUAL should be read and understood If in doub...

Страница 2: ...FX 10GM POSITIONING CONTROLLER ii...

Страница 3: ...e completed equipment should be trained to use that product in a safe and co ordinated manner in compliance to established safety practices The operators should also be familiar with documentation whi...

Страница 4: ...iguration 1 3 1 3 External Dimensions 1 4 2 SPECIFICATIONS 2 1 2 1 General Specifications 2 1 2 2 Power Supply Specifications 2 1 2 2 1 Power Supply Specifications 2 1 2 2 2 Service power supply 2 2 2...

Страница 5: ...o motor via the drive unit Number of control axes Positioning languages Number of output pulses Connection to Programmable controller 1 Dedicated language Sequence language 1 to 200 kPPS Connected to...

Страница 6: ...nit block for the programmable controller Mounting hole 2 5 5 DIN rail Not used when the unit is mounted to a DIN rail Operation indicator LEDs I O output status indicator LEDs 2C MANU COM1 1 2 System...

Страница 7: ...Y7 COM3 Y11 Y13 COM4 Y15 Y17 PULL 24 24 COM1 MANU B POWER 3 7 0 4 1 5 2 6 3 7 0 4 1 5 2 6 A POWER 3 7 0 4 1 5 2 6 3 7 0 4 1 5 2 6 TRANSISTOR BLOCK A B 24 24 COM1 MANU 1 0 1 2 3 COM COM 4 5 6 7 COM COM...

Страница 8: ...5 6 Various data settings can be fetched through connections that save wiring either by a direct connection method or by multiplexing input outputs General output extension output 1 Auxiliary equipme...

Страница 9: ...d Stop command Zero return command 2 Mechanical system inputs Forward rotation limit Reverse rotation limit Near point dog signal Manual forward rotation command Manual reverse rotation command Manual...

Страница 10: ...ZRN STOP Y5 X0 X1 X2 X3 Y0 Y1 Y2 Y3 Y4 CLR MANU SVRDY SVEND PGO FP RP CPU E POWER READY ERROR 140 125 Width 35mm DIN rail moun ting groove 10 40 50 95 2 5 5 Mounting hole 1 3 External Dimensions Weig...

Страница 11: ...not allowed 2 Ambient atmosphere Free from corrosive gas and excessive dust 1 0 5G when mounted to a DIN rail 2 2 SPECIFICATIONS For complefe operation wiring mounting and programming instructions ple...

Страница 12: ...ormance Specifications Item Specifications Number of control axes 1 Applicable programmable controller Bus connection with FX FX2C Series PC Number of I O points occuupied 8 points Program memory 3 8k...

Страница 13: ...with instruction cods 13 types Sequence 11 types LD LDI AND ANI OR ORI ANB ORB SET RST NOP Application FNC No system 29 types M codes maintask m00 WAIT program stop and m02 END m01 m03 to m99 can be...

Страница 14: ...r less 0 3 mA or less PG0 0 5 mA or less Signal format Contact input or NPN open collector transistor input Response time Group 1 Approx 0 5 msec Approx 3 msec Group 2 Approx 3 msec Approx 3 sec Group...

Страница 15: ...utput is ON LED is lit while output is ON External power supply 5 to 24V DC 10 5 to 24V DC 10 Load current 20 mA or less 50 mA or less Open circuit leak current 0 1 mA 24V DC or less 0 1 mA 24V DC or...

Страница 16: ...connector cables made by the user and for the connectors to be used when connecting additional equipment are indicated below 1 When making a cable Flat cables Wire size AWG28 0 1 mm2 1 27 pitch 20 co...

Отзывы: