58
Function (Parameter) list
P
ara
me
te
r L
ist
Calibration parameters
* Factory settings may differ because of calibration parameters.
Func-
tion
Parame-
ters
Indi-
cation
Name
Setting Range
Minimum
Setting
Incre-
ments
Factory
Setting
Refer
To:
Cus-
tomer
Setting
Ca
lib
ra
tio
n p
a
ra
me
te
rs
C1 (901)
AM terminal
calibration
126
C2 (902)
Frequency
setting voltage
bias frequency
0 to 60Hz
0.1Hz
0Hz
82
C3 (902)
Frequency setting
voltage bias
0 to 300%
0.1%
0% (*)
82
C4 (903)
Frequency setting
voltage gain
0 to 300%
0.1%
96%
(*)
82
C5 (904)
Frequency
setting current
bias frequency
0 to 60Hz
0.1Hz
0Hz
82
C6 (904)
Frequency setting
current bias
0 to 300%
0.1%
20% (*)
82
C7 (905)
Frequency setting
current gain
0 to 300%
0.1%
100%
(*)
82
C8 (269)
Parameter for manufacturer setting. Do not set.
Cle
a
r p
a
ra
me
te
rs
CLr
Parameter clear
0: Not executed
1: Parameter clear
10: All clear
1
0
129
ECL
Alarm history
clear
0: Not cleared,
1: Alarm history
clear
1
0
129
Содержание FR - S500
Страница 56: ...46 MEMO ...
Страница 164: ...154 MEMO ...
Страница 188: ...178 MEMO ...