![Mitsubishi FR - S500 Скачать руководство пользователя страница 67](http://html1.mh-extra.com/html/mitsubishi/fr-s500/fr-s500_instruction-manual_1809246067.webp)
57
Function (Parameter) list
2
F
UNCT
IO
NS
P
ara
me
te
r L
ist
Maintenance parameters
Additional parameters
Parameter for manufacturer setting
Func-
tion
Parame-
ters
Indi-
cation
Name
Setting Range
Minimum
Setting
Incre-
ments
Factory
Setting
Refer
To:
Cus-
tomer
Setting
M
a
in
te
nan
ce f
unc
ti
on
H1 (503)
Maintenance
timer
0 to 999
1
(1000h)
0
122
H2 (504)
Maintenance
timer alarm output
set time
0 to 999, - - -
1
(1000h)
36
(36000h) 122
H3 (555)
Current average
time
0.1 to 1s
0.1s
1s
123
H4 (556)
Data output mask
time
0 to 20s
0.1s
0s
123
H5 (557)
Current average
value monitor
signal output
reference current
0.1 to 999A
0.1A
1A
123
Func-
tion
Parame-
ters
Indi-
cation
Name
Setting Range
Minimum
Setting
Incre-
ments
Factory
Setting
Refer
To:
Cus-
tomer
Setting
Addit
io
n
al
func
ti
on
H6 (162)
Automatic restart
after instantaneous
power failure
selection
0, 1, 10
1
1
92
H7 (559)
Second electronic
thermal O/L relay 0 to 50A, - - -
0.1A
- - -
69
Func-
tion
Parame-
ters
Indi-
cation
Name
Setting Range
Minimum
Setting
Incre-
ments
Factory
Setting
Refer
To:
Cus-
tomer
Setting
–
b1 (560)
Parameter for manufacturer setting. Do not set.
b2 (561)
Содержание FR - S500