152
Parameter unit (FR-PU04) setting
2.16.3 PU contrast adjustment (n15
)
The parameter number in parentheses is the one for use with the parameter unit (FR-
PU04).
2.16.4 PU main display screen data selection (n16
)
The parameter number in parentheses is the one for use with the parameter unit (FR-
PU04).
<Setting>
When "100" is set in n16, the monitor value is different depending on whether the
inverter is at a stop or running.
By setting the communication parameter n15 "PU contrast adjustment", you can
adjust the LCD contrast of the parameter unit (FR-PU04). When using the FR-
PU04, adjust the numerical value to any darkness with the
/
and define
that brightness with the
of the parameter unit.
Parameter
Name
Factory
Setting
Setting
Range
Remarks
n15 (991)
PU contrast adjustment
58
0 to 63 Setting is enabled when Pr. 30 = "1"
CAUTION
When using the FR-PU04, you should press the
to store the PU contrast
setting value.
You can choose the main display screen of the parameter unit (FR-PU04).
Parameter
Name
Factory
Setting
Setting
Range
Remarks
n16 (992)
PU main display
screen data
selection
0
0, 100 Setting is enabled when Pr. 30 = "1"
n16
0
100
During operation/stop
During stop
During operation
Output frequency
Output frequency
Set frequency
Output frequency
Output current
Output current
Alarm display
Alarm display
REMARKS
•
During an error, the output frequency at error occurrence appears.
•
During MRS, the values displayed are the same as during a stop.
♦
Related parameters
♦
•
Speed display
⇒
Pr. 37 "speed display" (refer to page 81)
WRITE
WRITE