235
FDTN-H
Power source
3 Phase 380/415V 50Hz
Indoor Unit
TB
Outdoor Unit
RD/WH
BK/WH
BK/RD
BL/WH
BR/WH
Y/GN
BK
DR
DR
Tho-R
63H
2
CnL
LED-R
LED-G
(Check)
(Run)
CnE
Vao
(Checker)
CnA1
Tro
CnA2
BK
Tho-D
BK
Tho-A
6
14V
27
BL/WH
BK/RD
BR/WH
BL
BL
BL
BL
P
P
BR
BR
BK
BK
26
25
23
22
21
20
19
18
17
16
13
12
2
1
13
24
5
6
Printed Circuit Board
3
HL
UH
A1
CF
01
A2
28
X
05
X
02
X
01
X
03
X
04
X
06
X
08
X
07
X
01
220/240V
7
PC
PC
CnR
CnM
1
CH
X
04
X
07
X
02
X
05
X
08
X
03
X
06
1
2/N
3
4
5
F(3.15A)
OR/WH
OR/WH
OR
OR
WH
BR
BL
BK
BL
RD
Y/GN
WH
WH
BL
RD
WH
BL
BK/WH
RD
CT2
CT1
V
UW
52C
RD/WH
RD
BK/WH
WH
L
3
L
1
N
L
2
TB
SV
2
SV
1
52C
20S
FM
O1
(49F
O1
)
CM
LM
FM
I
(49F
I
)
DM
Y/GN
RD
WH
BK
TB
1
2
9
X
1
X
3
X
4
X
7
X
5
X
2
WH
WH
WH
OR
OR
RD
RD
BL
BK
BL
BK
WH
WH
Y/GN
CnJ
CnF
1
CF
I
3
87
6
5
L
H
UH
OR
WH
WH
RD
WH
RD
BR
BR
GR
CnF
1
CnJ
CnR
Cn
I
Cn
I
CnR
4
13
X
1
X
2
X
3
X
4
X
7
X
5
Va
l
CnT
CnH
CnN
CnL
CnV
CnB
2
CnB
CnA
CnN
CnH
2
Th
I
–A
Th
I
–R
BK
BK
BK
BK
RD
RD
BK
BK
BK
RD
BK
BR
CnW
1
CnW
2
CnQ
Tr
I
T
est
XR1
XR2
XR3
XR4
XR5
Option
Receiver amp
Wireless
remote
controller
LED1
LED2
SW
( 3 )
( 3 )
( 3 )
SW2
SW3
ON
ON
OFF
OFF
1 2 3 4
1 2 3 4
PC
FS
X
6
BL
BR
PC
10
14
X
6
220/240V
12V
1
2/N
3
4
5
CnS
CnB
Remote controller
BK
BK
RD
WH
BK
RD
WH
BK
Thc
BK
LS
CnS2
BK
Only case of FDT
series.
1
1
Y
Y
Z
Z
X
X
Printed wiring board
Models
FDTN308HES-S
FDT308HES-S
Color mark
Mark
Color
BK
Black
BL
Blue
BR
Brown
GR
Gray
OR
Orange
P
Pink
RD
Red
WH
White
Mark
Color
BK/RD
Black/Red
BK/WH
Black/White
BL/WH
Blue/White
BR/WH
Brown/White
OR/WH
Orange/White
RD/WH
Red/White
Y/GN
Y
ellow/Green
]
This diagram indicates the FDTN series. Section from
1 changes on
the FDT series.
[
Meaning of marks
Mark
Parts name
Mark
Parts name
CF
I
Capacitor for FM
I
Th
I
-R
Thermistor
CF
O1
Capacitor for FM
O
Tho-A
Thermistor
CH
Crankcase heater
Tho-D
Thermistor
CM
Compressor motor
Tho-R
Thermistor
CnA ~ Z
Connector (
□
mark)
Tr
I
T
ransformer (Indoor unit)
CT
1,2
Current sensor
Tr
O
T
ransformer (Outdoor unit)
F
Fuse
Va
l
V
aristor
FM
I
Fan motor (Indoor unit)
Va
o
V
aristor
FM
O1
Fan motor (Outdoor unit)
20S
4-way valve solenoid
LM
Louver motor
49F
I
Internal thermostat for FM
I
LS
Limit switch
49F
O1
Internal thermostat for FMo
DM
Drain motor
52C
Magnetic contactor for CM
FS
Float switch
X1~7
Auxiliary relay
PC
Photo coupler
X
01~08
Auxiliary relay
SV
1,2
Solenoid coil (for control)
63H
2
High pressure switch (for control)
SW
Switch (ON/OFF)
v
T
erminal (F)
SW2, 3
Changeover switch
■
Connector
TB
T
erminal block (
嘷
mark)
LED-G
Indication lamp (Green)
Thc
Thermistor
LED-R
Indication lamp (Red)
Th
I
-A
Thermistor
Содержание FDT208HEN-S