![Mitsubishi DX-VS1 Скачать руководство пользователя страница 55](http://html1.mh-extra.com/html/mitsubishi/dx-vs1/dx-vs1_user-manual_1809758055.webp)
DX-VS1UE User’s Manual
54
PTZ Command for Manual Script
1. Escape Characters
#
Special command
@
Hexadecimal character
%
Decimal character
^
Character
,
Break character
;
End of current packet
&
Special operation
2. Special command (Followed by #)
A
Address assigned by pan/tilt/zoom configuration
X
Acceleration rate selected by user
S
x
Checksum calculation method
x
= 0
Sum of entire frame, size = 1byte
x
= 1
Sum of entire frame, size = 2byte
x
= 2
Sum of entire frame except first byte (sync), size = 1byte
x
= 3
Sum of entire frame except first byte (STX) and last byte (ETX), size = 1byte
x
= 4
Sum and one's complement of entire frame except first byte (STX) and last byte (ETX),
size = 1byte
x
= 5
XOR sum of entire frame, size = 1byte
x
= 6
XOR sum of entire frame, size = 2byte
x
= 7
XOR sum of entire frame except first byte (sync), size = 1byte
x
= 8
XOR sum of entire frame except first byte (STX) and last byte (ETX), size = 1byte
x
= 9
XOR sum and one's complement of entire frame except first byte (STX) and last byte (ETX),
size = 1byte
3. Special Operation (Followed by &)
S
x
Delay about ( ([
acceleration rate
] + 1) * (100 *
x
) ) ms
x
0 ~ 4
4. Exceptions
Normal character following Escape Sequence, must use break character for identifying the end of sequence
* Some protocols are not to be made command script with above method. It is because they use another
method of checksum calculation.