TROUBLESHOOTING
Air dryer
Symptoms
Deposits come out of drain cock of air tank
No deposits come out of exhaust port
Freezing takes place within air dryer
Air pressure in air tank decreases markedly
Engine oil leaks from exhaust port
Reference
Gr
Possible causes
Deterioration of desiccating agent
O
Inoperative heater causing air dryer to freeze
O
Malfunctioning of valve due to adherence of foreign particles
O
Heater circuit open and therefore no heat retention
O
Heater malfunction due to thermostat malfunction
O
Extreme lowering of temperature of air dryer main body due to ad-
herence of snow/ice
O
Heater malfunction due to disconnection with thermostat
O
Dry air in air tank flows out in reverse when check valve of air dryer
fails to function as a non-return valve
O
Rising of oil level in air compressor
O
Содержание 6M60-TL
Страница 1: ...Service Manual 99709 51100 For use with the FD80N FD160N Service Manuals 6M60 TL Diesel Engine ...
Страница 2: ......
Страница 8: ...00 00 5 ...
Страница 26: ...00 00 23 212340 OutputUnit V OutputUnit OutputUnit ...
Страница 27: ...00 24 3 2 2 VCM 3OP input monitor and output monitor VCM 3 VCM 3OP 212341 ...
Страница 28: ...00 00 25 3 2 3 MP input monitor VCM 3 MP 212342 ...
Страница 45: ...M E M O 11 9 11 ...
Страница 51: ...M E M O 11 15 11 ...
Страница 52: ...11 16 ROCKER COVER ROCKER BRACKET AND CAMSHAFT ...
Страница 60: ...11 24 CYLINDER HEAD AND VALVE MECHANISM ...
Страница 67: ...M E M O 11 31 11 ...
Страница 83: ...M E M O 11 47 11 ...
Страница 89: ...M E M O 11 53 11 ...
Страница 97: ...M E M O 11 61 11 ...
Страница 103: ...M E M O 11 67 11 ...
Страница 104: ...11 68 CRANKSHAFT AND CRANKCASE ...
Страница 142: ...M E M O 13A 9 13A ...
Страница 152: ...M E M O 13A 19 13A ...
Страница 161: ...M E M O 13E 3 13E ...
Страница 164: ...13E 6 1 1 Supply pump STRUCTURE AND OPERATION ...
Страница 176: ...13E 18 3 Electronic Control Unit Connection Diagram STRUCTURE AND OPERATION ...
Страница 177: ...13E 13E 19 ...
Страница 212: ...14 14 3 1 Cooling System Flow of Coolant STRUCTURE AND OPERATION ...
Страница 220: ...M E M O 14 11 14 ...
Страница 236: ...M E M O 14 27 14 ...
Страница 255: ...M E M O 15 13 15 ...
Страница 272: ...54 54 3 1 Starter This starter uses planetary gears as its reduction gearing mech anism STRUCTURE AND OPERATION ...
Страница 273: ...54 4 2 Alternator 24V 50A STRUCTURE AND OPERATION ...
Страница 276: ...54 54 7 3 Circuit diagram ...
Страница 308: ...M E M O 61 3 61 ...
Страница 309: ...61 4 1 Air Compressor STRUCTURE AND OPERATION ...
Страница 318: ...M E M O 61 13 61 ...
Страница 319: ...61 14 AIR COMPRESSOR 154 cm3 154 mL ...
Страница 322: ...M E M O 61 17 61 ...
Страница 323: ...61 18 AIR COMPRESSOR 319 cm3 319 mL ...
Страница 326: ...M E M O 61 21 61 ...
Страница 327: ...61 22 AIR DRYER ...