79
–
E7
Intake air temperature thermistor anomaly
Keeps flashing 1 time flash
Keeps flashing
Stays Off
1. Applicable model
5. Troubleshooting
All models
Diagnosis
Countermeasure
NO
NO
YES
Is the
connection of intake air
temperature sensor connector
OK?
Are the
characteristics of intake air
temperature sensor
OK?
YES
15
10
5
0
10
30
40
20
50
Temperature-resistance characteristic
Temperature sensor resistance (k
Ω
)
Temperature (°C)
Note (1) 22.5k
Ω
at -6
°C
5k
Ω
at 25
°C
Correct.
Connect
connector.
Defective intake air
temperature thermistor
Replace.
Defective indoor control
PCB
Replace.
(Defective intake air
temperature thermistor
input circuit)
2. Error detection method
Anomalously low temperature
or high temperature (resistance)
is detected by indoor intake air
temperature thermistor (Thi-A)
3. Condition of error displayed
• When the temperature sensor
detects -50°C or lower for
5 seconds continuously,
the compressor stops.
After 3-minute delay, the
compressor starts again
automatically, but if this
anomaly occurs again within
60 minutes after the initial
detection.
• Or if 48°C or higher is
detected for 5 seconds
continuously.
4. Presumable cause
• Defective intake air
temperature thermistor
connector
• Defective intake air
temperature thermistor
• Faulty indoor control PCB
Note:
Error code
Remote control:
7-segment display:
LED
Green
Red
Indoor
Outdoor
Content
'17 • KX-SM-272