APPENDIX
App. - 7
(2) Selection example of wires
To comply with UL 1004-1 and CSA-C22.2 No. 100, use UL-approved copper wires rated at 75 °C for
wiring.
The following table shows the wire size [AWG] rated at 75 °C, which is used for wiring of TM-RFM, TM-
RG2M and TM-RU2M series.
(a) TM-RFM series
Direct drive motor
Wire [AWG]
U/V/W/
TM-RFM002C20
TM-RFM004C20
TM-RFM006C20
TM-RFM006E20
16 (Note 2)
TM-RFM012E20
TM-RFM018E20
TM-RFM012G20
TM-RFM048G20
12
TM-RFM072G20
TM-RFM040J10
16 (Note 2)
TM-RFM120J10 12
TM-RFM240J10
10 (Note 1)
Note 1. Refer to each servo amplifier instruction manual for crimp terminals used for
connection with the servo amplifier.
2. To comply with UL 508A and NFPA 79, AWG 14 or more is required.
(b) TM-RG2M series and TM-RU2M series
Direct drive motor
Wire [AWG]
U/V/W/
TM-RG2M002C30
18 (Note)
TM-RU2M002C30
TM-RG2M004E30
TM-RU2M004E30
TM-RG2M009G30
TM-RU2M009G30
Note. To comply with UL 508A and NFPA 79, AWG 14 or more is required.