5. CONNECTION OF SERVO AMPLIFIER AND DIRECT DRIVE MOTOR
5 - 6
(c) MR-J4W_ - _B
Servo amplifier
CNP3A
CNP3B
CNP3C
(Note)
Note. For the 3-axis servo amplifier.
Table 5.3 Connector and applicable wire
Connector Receptacle
assembly
Applicable wire
size
Stripped length
[mm]
Open tool
Manufacturer
CNP3A
CNP3B
CNP3C
04JFAT-SAGG-G-KK
AWG 18 to 14
9
J-FAT-OT-EXL
JST
(2) Cable connection procedure
(a) Fabrication on cable insulator
Refer to tables 5.1 to 5.3 for stripped length of cable insulator. The appropriate stripped length of
cables depends on their type, etc. Set the length considering their fabrication status.
Insulator
Core
Stripped length
Twist strands lightly and straighten them as follows.
Loose and bent cores
Twist and straighten
the cores.