5. CONNECTION OF SERVO AMPLIFIER AND DIRECT DRIVE MOTOR
5 - 3
5.3 Selection example of wires
POINT
Wires indicated in this section are separated wires.
Selection condition of wire size is as follows.
Construction condition: Single wire set in midair.
Wire length: 30 m or less
The following shows examples for using the 600 V Grade heat-resistant polyvinyl chloride insulated wire
(HIV wire).
(1) TM-RFM series
Direct drive motor
Wire [mm
2
]
U/V/W/
TM-RFM002C20
TM-RFM004C20
TM-RFM006C20
TM-RFM006E20
1.25 (AWG 16)
TM-RFM012E20
TM-RFM018E20
TM-RFM012G20
TM-RFM048G20
3.5 (AWG 12)
TM-RFM072G20
TM-RFM040J10
1.25 (AWG 16)
TM-RFM120J10
3.5 (AWG 12)
TM-RFM240J10
5.5 (AWG 10) (Note)
Note. Refer to each servo amplifier instruction manual for crimp terminals used for
connection with the servo amplifier.