18
Also consider operation sound
• Do not put an object around the air outlet of the outdoor unit. It may cause lowering of capacity or increase operating sound.
• If abnormal sound is heard during operation, consult your dealer.
Relocation
• When the air conditioner is to be removed or reinstalled because of rebuilding, moving, etc., special techniques and work are required.
Warning:
Repair or relocation should not be done by the customer.
If this is done incorrectly, it may cause a fire, electric shock, injury by dropping of the unit, water leakage, etc. Consult your dealer.
Disposal
• To dispose of this product, consult your dealer.
If you have any question, consult your dealer.
12. Installation, relocation and inspection
13. Specifications
Model
SLZ-KA25VAQ
SLZ-KA25VAL
SLZ-KA35VAQ
SLZ-KA35VAL
SLZ-KA50VAQ
SLZ-KA50VAL
Power Supply (Voltage <V>, Frequency<Hz>)
~/N, 230V, 50Hz
Rated Input (Indoor only)
<kW>
0.075
0.085
0.085
Rated Current (Indoor only)
<A>
0.35
0.40
0.65
Dimension (Height)
<mm>
235 (20)
Dimension (Width)
<mm>
570 (650)
Dimension (Depth)
<mm>
570 (650)
Fan airflow rate (Low-Middle-High)
<m
3
/min>
8 - 9 - 10
8 - 9 - 11
8 - 9 - 11
Noise level (Low-Middle-High)
<dB>
28 - 31 - 37
29 - 33 - 38
30 - 34 - 39
Net weight
<kg>
16.5 (3)
Notes: 1. This figure ( ) indicates GRILLE’S.
2. Specifications subject to change without notice.
Guaranteed operating range
Indoor
Outdoor
Cooling
Upper limit
32°C DB, 23°C WB
46°C DB, –
Lower limit
21°C DB, 15°C WB
-10°C DB, –
Heating
Upper limit
27°C DB, –
24°C DB, 18°C WB
Lower limit
20°C DB, –
-10°C DB, -11°C WB
Units should be installed by licensed electric contractor accordingly to local code requirement.