15
When the remote controller cannot be used
When the batteries of the remote controller run out or the remote controller
malfunctions, the emergency operation can be done using the emergency
buttons on the grille.
A
DEFROST/STAND BY lamp
B
Operation lamp
C
Emergency operation switch (heating)
D
Emergency operation switch (cooling)
E
Receiver
Starting operation
• To operate the cooling mode, press the
button
D
.
• To operate the heating mode, press the
button
C
.
Note:
• Details of emergency mode are as shown below.
Details of EMERGENCY MODE are as shown below.
Operation mode
COOL
HEAT
Set temperature
24°C
24°C
Fan speed
High
High
Airflow direction
Horizontal
Downward 4
Stopping operation
• To stop operation, press the
button
D
or the
button
C
.
9. Emergency Operation for Wireless Remote-controller
ON/OFF
TEMP.
°C
°C
FILTER
N
Indicates that the filter needs cleaning.
Clean the filter.
N
When resetting “FILTER” display
When the [FILTER] button is pressed two times successively after clean-
ing the filter, the display goes off and is reset.
Note:
●
When two or more different types of indoor unit are controlled, the cleaning
period differs with the type of filter. When the master unit cleaning period
arrives, “FILTER” is displayed. When the filter display goes off, the cumula-
tive time is reset.
●
“FILTER” indicates the cleaning period when the air conditioner was used
under general indoor air conditions by criteria time. Since the degree of
dirtiness depends on the environmental conditions, clean the filter accord-
ingly.
●
The filter cleaning period cumulative time differs with the model.
●
This indication is not available for wireless remote controller.
► Cleaning the filters
• Clean the filters using a vacuum cleaner. If you do not have a vacuum
cleaner, tap the filters against a solid object to knock off dirt and dust.
• If the filters are especially dirty, wash them in lukewarm water. Take care
to rinse off any detergent thoroughly and allow the filters to dry completely
before putting them back into the unit.
Caution:
• Do not dry the filters in direct sunlight or by using a heat source,
such as an electric heater: this may warp them.
• Do not wash the filters in hot water (above 50°C), as this may warp
them.
• Make sure that the air filters are always installed. Operating the unit
without air filters can cause malfunction.
Caution:
• Before you start cleaning, stop operation and turn OFF the power
supply.
• Indoor units are equipped with filters to remove the dust of sucked-
in air. Clean the filters using the methods shown in the following
sketches.
10. Care and Cleaning
► Filter removal
Caution:
• In removing the filter, precautions must be taken to protect your
eyes from dust. Also, if you have to climb up on a stool to do the
job, be careful not to fall.
• When the filter is removed, do not touch the metallic parts inside
the indoor unit, otherwise injury may result.
N
SLZ-KA·VAQ/SLZ-KA·VAL
1
Pull the knob on the intake grille in the direction indicated by the arrow
and it should open.
2
Open the intake grille.
3
Release the knob on the center edge of the intake grille and pull the
filter forward to remove the filter.
A
Knob
B
Grille
C
Intake grille
D
Filter
SLP-2ALW (For SLZ-KA25/KA35/KA50VAL)