2 PARAMETER SETTINGS
2.3 Basic Settings
The link devices of the Simple Motion module can be accessed from a program. (
1 to 256
Link Side
Set the link refresh ranges of RX, RY, RWr, and RWw. Up to 256 ranges can be
set. (
Device Name
• RX, RY, RWr, RWw
(Default: Blank)
Points
• RX, RY: 16 to 16384
• RWr, RWw: 4 to 8192
(Default: Blank)
Start
• RX, RY: 0H to 3FF0H (set in increments of
16 points)
• RWr, RWw: 0 to 1FFCH (set in increments
of 4 points)
(Default: Blank)
End
• RX, RY: 0H to 3FFFH (set in increments of
16 points)
• RWr, RWw: 0 to 1FFFH (set in increments
of 4 points)
(Default: Blank)
CPU Side
Target
• Specify Device
(Default: Blank)
Device Name
• Specify Device (when link side is RX): X, M,
L, B, D, W, R, ZR, RD
• Specify Device (when link side is RY): Y, M,
L, B, D, W, R, ZR, RD
• Specify Device (when link side is RWr): M,
L, B, D, W, R, ZR, RD
• Specify Device (when link side is RWw): M,
L, B, D, W, R, ZR, RD
(Default: Blank)
Points, Start, End
• Range of the device in the CPU module
• Set bit devices in increments of 16 points
and word devices in increments of 4 points.
(Default: Blank)
Item
Description
Setting range
0000H
00FFH
0000H
00FFH
1000H
10FFH
0000H
00FFH
1000H
10FFH
0000H
00FFH
000000H
0000FFH
001000H
0010FFH
Transfer
1
Transfer
2
Transfer
3
Transfer
4
Device
name
(RX)
Device
name
(RY)
Device
name
(RWr)
Device
name
(RWw)
Device
name
(W)
Device
name
(W)
Device
name
(Y)
Device
name
(X)
Simple Motion module
CPU module
Ex.