1 FUNCTIONS
1.5 IP Packet Transfer Function
Precautions when configuring a multiple CPU system
Set a CPU module connected to an Ethernet device as a control CPU of the Simple Motion module performing the IP packet transfer.
Any CPU module in a relay station on CC-Link IE Field Network can be served as a control CPU of the Simple Motion module transferring the IP packet.
When multiple Simple Motion modules or master/local modules with the same network No. are connected to one system, the Simple Motion module or the
master/local module with the smallest slot No. transfers the IP packet. To transfer the IP packet, connect the Ethernet device to a control CPU of the Simple
Motion module or the master/local module with the same network No. and smallest slot No.
Ethernet
Ethernet
3
Ethernet
Simple Motion module
Simple Motion module
Ethernet device
(request source device)
CPU module on
CC-Link IE Field Network
(No restrictions on the control CPU)
Ethernet device
(request destination device)
Module mounted on
the smallest slot No.
CC-Link IE Field Network
Control
CPU module connected to
an Ethernet device
Ethernet device
(request source device)
Control
Same network No.
CC-Link IE Field
Network