![Mitsubishi Electric RD77GF16 Скачать руководство пользователя страница 100](http://html.mh-extra.com/html/mitsubishi-electric/rd77gf16/rd77gf16_user-manual_1811854100.webp)
98
3 PROGRAMMING
3.2 Communication Example of Safety Communication Function
Program examples
The following shows a program example of each station when the safety program and safety global device are used.
Program example
• Master station (station No.0)
Classification
Device
Description
Safety special register
SA\SD1008.0
Safety refresh communication status of each safety connection (1st module) (safety connection
No.1)
SA\SD1008.1
Safety refresh communication status of each safety connection (1st module) (safety connection
No.2)
SA\SD1232.0
Interlock status of each safety connection (1st module) (safety connection No.1)
SA\SD1232.1
Interlock status of each safety connection (1st module) (safety connection No.2)
SA\SD1240.0
Interlock release request for each safety connection (1st module) (safety connection No.1)
SA\SD1240.1
Interlock release request for each safety connection (1st module) (safety connection No.2)
Label to be defined
Define safety global labels as shown below:
(0) Processing to release the safety station interlock status in safety communications with station No.1
(6) Communication program with station No.1
(14) Processing to release the safety station interlock status in safety communications with station No.2
(20) Communication program with station No.2