Appendix 4 List of Link Special Register (SW)
SW0198
Link dedicated
instructions processing
result CH3
Stores the processing results of the link dedicated instruction that used channel 3 of the own station.
0: Completed normally
1 or greater: Completed with an error (Error code is stored.)
SW0199
Link dedicated
instructions processing
result CH4
Stores the processing results of the link dedicated instruction that used channel 4 of the own station.
0: Completed normally
1 or greater: Completed with an error (Error code is stored.)
SW019A
Link dedicated
instructions processing
result CH5
Stores the processing results of the link dedicated instruction that used channel 5 of the own station.
0: Completed normally
1 or greater: Completed with an error (Error code is stored.)
SW019B
Link dedicated
instructions processing
result CH6
Stores the processing results of the link dedicated instruction that used channel 6 of the own station.
0: Completed normally
1 or greater: Completed with an error (Error code is stored.)
SW019C
Link dedicated
instructions processing
result CH7
Stores the processing results of the link dedicated instruction that used channel 7 of the own station.
0: Completed normally
1 or greater: Completed with an error (Error code is stored.)
SW019D
Link dedicated
instructions processing
result CH8
Stores the processing results of the link dedicated instruction that used channel 8 of the own station.
0: Completed normally
1 or greater: Completed with an error (Error code is stored.)
SW01C0
to
SW01C7
Information of CC-Link
IE Field Network
synchronous
communication function
of each station
Stores the information about support or non-support of CC-Link IE Field Network synchronous communication function
for each station.
0: Not supported
1: Supported
Each No. in the table represents a station No.
is fixed to 0.
(Conditions)
• This register is enabled when "Baton pass status of own station" (SB0047) is off.
• When "Baton pass status of own station" (SB0047) is turned on (error), data prior to error is held.
• This register is enabled only for normally operating stations in "Baton pass status of each station" (SW00A0 to
SW00A7).
• Stations higher than the maximum station No. are ignored.
SW01C8
to
SW01CF
Synchronous/
asynchronous operating
status information of
each station
Stores the information about operating status of CC-Link IE Field Network synchronous communication function for
each station.
0: Asynchronous setting
1: Synchronous setting
Stations which are not executing an inter-module synchronous interrupt program because the CPU operating status is
currently a status such as STOP, that is unable to execute the program, are also treated as an asynchronous setting.
Each No. in the table represents a station No.
is fixed to 0.
(Conditions)
• This register is enabled when "Baton pass status of own station" (SB0047) is off.
• When "Baton pass status of own station" (SB0047) is turned on (error), data prior to error is held.
• This register is enabled only for normally operating stations in "Baton pass status of each station" (SW00A0 to
SW00A7).
• Stations higher than the maximum station No. are ignored.
No.
Name
Description
16 15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33
64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49
80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65
96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81
112 111 110 109 108 107 106 105 104 103 102 101 100 99 98 97
120 119 118 117 116 115 114 113
SW01C1
SW01C2
SW01C3
SW01C4
SW01C5
SW01C6
SW01C7
SW01C0
16 15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33
64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49
80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65
96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81
112 111 110 109 108 107 106 105 104 103 102 101 100 99 98 97
120 119 118 117 116 115 114 113
SW01C9
SW01CA
SW01CB
SW01CC
SW01CD
SW01CE
SW01CF
SW01C8
Содержание RD77GF16
Страница 1: ...MELSEC iQ R Simple Motion Module User s Manual Network RD77GF4 RD77GF8 RD77GF16 RD77GF32 ...
Страница 2: ......
Страница 181: ...I 179 MEMO ...
Страница 185: ......