1 FUNCTIONS
1.1 Fixed Cycle Communication
17
1
1
FUNCTIONS
1.1
Fixed Cycle Communication
The communication cycle of the Simple Motion module is fixed cycle. The communication is performed with slave modules in
a cycle set in the inter-module synchronization cycle setting.
Refer to the following for details.
MELSEC iQ-R Inter-Module Synchronization Function Reference Manual
1.2
CC-Link IE Field Network Synchronous
Communication Function
A slave module which supports the CC-Link IE Field Network synchronous communication function operates synchronously
with the inter-module synchronization cycle of the Simple Motion module (the communication cycle of CC-Link IE Field
Network). Therefore, the operation timing between the Simple Motion module and each slave module can be synchronized.
A slave module which does not support the CC-Link IE Field Network synchronous communication function is also
connectable. However, the operation is not synchronized with the inter-module synchronization cycle of the Simple Motion
module. Therefore, the operation timing of the slave module is not synchronized with the Simple Motion module.
Refer to the following for details.
MELSEC iQ-R Inter-Module Synchronization Function Reference Manual