7 - 19 7 - 19
MELSEC-Q
7 PROGRAMMING FOR EXECUTING THE MASTER FUNCTION
4)
5)
6)
7)
8)
9)
10)
4) Select the parameter saving area.
When saving the parameters for master function and the auto
communication start setting, set "Master/Auto Comm." for "Parameter
Saving Area Selection".
Select "Master/Auto Comm. " Execute test button
5) Set "Save Request" for "Y17: Request for Saving Parameters to Flash
ROM".
Select "Save Request" Execute test button
6) Parameter saving to the flash ROM is started, and "Saving" is
displayed for "X06: Saving Parameters to Flash ROM".
7) Upon completion of the saving, "Saving Completed" is displayed for
"X07: Parameters Saved to Flash ROM".