4. Blower/Fan Assembly
Exercise caution when removing heavy parts.
1. Remove the Blower and Filter panel (along with filter
if installed) indicated in section 2.
2. Remove the (1 or 2) brackets that secure the coil
assembly. (Fig.11)
Fig. 11
3. Remove the door that covers the small enclosure
attached to the fan assembly (Fig.12). Unplug the
motor and route the wire harness out of the
enclosure.
4. Remove the (2) screws that secure the fan
assembly and slide out.
Fig. 12