6. Electrical work

6.1. Outdoor unit (Fig. 6-1, Fig. 6-2)

 

1

  Remove the service panel.

 

2

  Wire the cables referring to the Fig. 6-1 and the Fig. 6-2.

C

Fig. 6-1

A

  Indoor unit

B

  Outdoor unit

C

  Remote controller

D

  Main switch (Breaker)

E

 Earth

Fig. 6-2

A

B

D

D

A

A

A

B

C

E

E

E

For Power

For Power

L N

S1 S2 S3

J

J

Terminal block

Indoor/Outdoor connection terminal block (S1, S2, S3)

Service panel

Clamp

*  Clamp the cables so that they do not contact the center of the service panel or the gas valve.

Earth terminal

J

J

 

ZM35, 50

Note : 

If the protective sheet for the electrical box is removed during servicing, be sure to 

reinstall it.

 Caution:

Be sure to install N-Line. Without N-Line, it could cause damage to unit.

 

ZM60, 71

F

G

H

I

 

ZM35, 50

 

ZM60, 71

F

J

H

I

BH79D314H06_EN.indd   12

2017/02/10   8:46:55

Содержание PUZ-ZM-HA

Страница 1: ...resente manuale ed il manuale d installazione dell unità interna prima di installare il condizionatore d aria EΓΧEIPIΔIO OΔHΓIΩN EΓKATAΣTAΣHΣ Για σωστή και ασφαλή χρήση διαβάστε προσεκτικά αυτό το εγχειρίδιο καθώς και το εγχειρίδιο εγκατάστασης της εσωτερικής μονάδας προτού εγκαταστήσετε τη μονάδα του κλιματιστικού MANUAL DE INSTALAÇÃO Para uma utilização segura e correcta leia atentamente este ma...

Страница 2: ...ng product safety Use only accessories authorized by Mitsubishi Electric and ask a dealer or an au thorized technician to install them If accessories are incorrectly installed water leakage electric shock or fire may result Do not alter the unit Consult a dealer for repairs If alterations or repairs are not performed correctly water leakage electric shock or fire may result The user should never a...

Страница 3: ... capacity is larger than the specified capacity breakdown or fire may result 1 4 Before starting the test run Caution Turn on the main power switch more than 12 hours before starting operation Starting operation just after turning on the power switch can severely damage the internal parts Keep the main power switch turned on during the operation season Before starting operation check that all pane...

Страница 4: ... situate the air outlet of the unit so that it is not directly exposed to strong winds Strong wind entering the air outlet may impede the normal airflow and a malfunction may result The following shows three examples of precautions against strong winds 1 Face the air outlet towards the nearest available wall about 500 mm away from the wall Fig 2 4 2 Install an optional air guide if the unit is ins...

Страница 5: ...ocally added refrigerant C Create an appropriate ventilation open area Make sure that the width of the open area is 0 9 m or more and the height of the open area is 0 15 m or more However the height from the bottom of the installation space to the bottom edge of the open area should be 0 125 m or less Open area should be 75 or more opening B Install in a space with a depression height of 0 125 m A...

Страница 6: ...tallation manual Install the indoor unit so that the height from the floor to the bottom of the indoor unit is h0 for wall mounted 1 8 m or more for ceiling suspended cassette and ceiling coucealed 2 2 m or more There are restrictions in installation height for each model so read the installation manual for the particular unit M kg Amin m 1 0 4 1 5 6 2 0 8 2 5 10 3 0 12 3 5 14 4 0 16 4 5 20 5 0 24...

Страница 7: ...zene oil small amount as the refrigeration oil applied to the flared sections Use C1220 copper phosphorus for copper and copper alloy seamless pipes to connect the refrigerant pipes Use refrigerant pipes with the thick nesses specified in the table to the below Make sure the insides of the pipes are clean and do not contain any harmful contaminants such as sul furic compounds oxidants debris or du...

Страница 8: ...y a thin layer of refrigeration oil Ap plied on site When usual pipe sealing is used refer to Table 1 for flaring of R32 refrigerant pipes The size adjustment gauge can be used to confirm A measurements Table 1 Fig 4 2 Copper pipe O D mm A mm Flare tool for R32 Flare tool for R22 R407C Clutch type ø6 35 1 4 0 0 5 1 0 1 5 ø9 52 3 8 0 0 5 1 0 1 5 ø12 7 1 2 0 0 5 1 0 1 5 ø15 88 5 8 0 0 5 1 0 1 5 ø19 ...

Страница 9: ...ipe connec tion sections of the outdoor unit Do not use the refrigerant from the unit to purge air from the refrigerant lines After the valve work is completed tighten the valve caps to the correct torque 20 to 25 N m 200 to 250 kgf cm Failure to replace and tighten the caps may result in refrigerant leakage In addition do not damage the insides of the valve caps as they act as a seal to prevent r...

Страница 10: ...l attached to the unit Refer to the 1 5 Using R32 refrigerant air conditioners for more information Be careful when installing multiple units Connecting to an incorrect indoor unit can lead to abnormally high pressure and have a serious effect on operation performance R32 maintenance refilling Before servicing refilling the equipment with R32 to ensure that there is no risk of explosion from elect...

Страница 11: ... pipes for ZM35 71 models The existing pipe thickness does not meet specifications or the pipes are damaged 4 Installing the refrigerant piping 5 Drainage piping work Outdoor unit drainage pipe connection When drain piping is necessary use the drain socket or the drain pan option ZM35 50 ZM60 71 Drain socket PAC SJ08DS E PAC SH71DS E Drain pan PAC SG63DP E PAC SG64DP E Limits of refrigerant piping...

Страница 12: ... E E For Power For Power L N S1 S2 S3 J J F Terminal block G Indoor Outdoor connection terminal block S1 S2 S3 H Service panel I Clamp Clamp the cables so that they do not contact the center of the service panel or the gas valve J Earth terminal J J ZM35 50 Note If the protective sheet for the electrical box is removed during servicing be sure to reinstall it Caution Be sure to install N Line With...

Страница 13: ... Max for PEA Wiring size 3 1 5 Polar 3 The 10 m wire is attached in the remote controller accessory 4 The figures are NOT always against the ground S3 terminal has 24 VDC against S2 terminal However between S3 and S1 these terminals are NOT electrically insulated by the transformer or other device Notes 1 Wiring size must comply with the applicable local and national code 2 Power supply cords and ...

Страница 14: ...med up at least 12 hours to prevent breakdown 4 If the insulation resistance rises above 1 M the compressor is not faulty Caution The compressor will not operate unless the power supply phase connection is correct Turn on the power at least 12 hours before starting operation Starting operation immediately after turning on the main power switch can result in severe damage to internal parts Keep the...

Страница 15: ... twin Refrigerant address 01 G Simultaneous triple Refrigerant address 02 E SW 1 3 6 F SW 1 3 6 G SW 1 3 6 A Fig 8 1 3 Because the unit automatically stops in about 2 to 3 minutes when the refrigerant collecting operation is completed LED1 off LED2 lit be sure to quickly close the gas stop valve If LED1 is lit and LED2 is off and the outdoor unit is stopped refrig erant collection is not properly ...

Страница 16: ...sabilidade que os aparelhos de ar condicionado e bombas de calor abaixo descritos para uso residencial comercial e de indústria ligeira erklærer hermed under eneansvar at de herunder beskrevne airconditionanlæg og varmepumper til brug i privat boligbyggeri erhvervsområder og inden for let industri intygar härmed att luftkonditioneringarna och värmepumparna som beskrivs nedan för användning i bostä...

Страница 17: ... Het Engels is het origineel De andere taalversies zijn vertalingen van het origineel VOORZICHTIG Het lekken van koelvloeistof kan verstikking veroorzaken Zorg voor ventilatie in overeenstemming met EN378 1 Isoleer de leidingen met isolatiemateriaal Direct contact met de onbedekte leidingen kan leiden tot brandwonden of bevriezing Stop nooit batterijen in uw mond om inslikking te voorkomen Het ins...

Страница 18: ...0 150 1000 300 200 1000 300 1000 1000 1000 300 500 400 1000 100 1000 400 2000 300 1000 500 150 Fig 2 7 Fig 2 8 Fig 2 9 Fig 2 10 Fig 2 11 Fig 2 12 Fig 2 13 Fig 2 14 Fig 2 15 Fig 2 16 Fig 2 17 Fig 2 18 Fig 2 19 UNIT mm Max 500 Max 500 Max 300 ...

Страница 19: ...sh Branch Westgate Business Park Ballymount Dublin 24 Ireland Italian Branch Centro Direzionale Colleoni Palazzo Sirio Ingresso 1 Viale Colleoni 7 20864 Agrate Brianza MB Italy Norwegian Branch Gneisveien 2D 1914 Ytre Enebakk Norway Portuguese Branch Avda do Forte 10 2799 514 Carnaxide Lisbon Portugal Spanish Branch Carretera de Rubi 76 80 Apdo 420 08173 Sant Cugat del Valles Barcelona Spain Scand...

Отзывы: