5
OCH668B
2
2-1. UNIT CONSTRUCTION
Remote
controller
Name
Model number
Functions
M-NET remote controller
PAR-F27MEA-E, PAR-U02MEDA
• A handy remote controller for use in
conjunction
with the Melans centralized
management system.
• Addresses must be set.
• Addresses setting is not
necessary.
MA remote controller
PAR-21MAA, PAR-31/32MAA
*1
When the indoor unit of Fresh Air type is connected with the outdoor unit, the maximum connectable total indoor unit capacity is 110%.
*2
PUMY is connectable to Fresh Air type indoor unit.
It is possible to connect 1 Fresh Air type indoor unit to 1 outdoor unit. (1:1 system)
Operating temperature range (outdoor temperature) for fresh air type indoor units differ from other indoor units.
Refer to "2-4-(3). Operating temperature range".
*3
When connecting the CONNECTION KIT (PAC-LV11M-J) and an M-series indoor unit, refer to the installation manual for the CONNECTION KIT.
*
4
Do not connect Lossnay remote controller(s). (PZ-61DR-E, PZ-60DR-E, PZ-52SF-E, PZ-43SMF-E)
*5
Authorized connectable indoor units are as follows;
PUMY-SP112:PEFY-P25VMA3-E×2 + PEFY-P32VMA3-E×2
PUMY-SP125: PEFY-P25VMA3-E×1 + PEFY-P32VMA3-E×3
PUMY-SP140: PEFY-P32VMA3-E×2 + PEFY-P40VMA3-E×2
*6
For the PLFY-EP/VEM-E, up to 2 units can be connected . Other indoor units (Excluding the PEFY-P/ VMA3-E and PEFY-P/ VMH-EF) can
be connected within the total rated capacity and maximum number of connected units.
*7
Connectable only for PUMY-SP▪VKMR1.TH(-BS),PUMY-SP▪YKMR1.TH(-BS).
OVERVIEW OF UNITS
Outdoor unit
4.5HP
5HP
6HP
PUMY-SP112VKM(R1).TH(-BS)
PUMY-SP112YKM(R1).TH(-BS)
PUMY-SP125VKM(R1).TH(-BS)
PUMY-SP125YKM(R1).TH(-BS)
PUMY-SP140VKM(R1).TH(-BS)
PUMY-SP140YKM(R1).TH(-BS)
Applicable
indoor unit
Capacity
Type 15 to Type 140
Number of units
1 to 9 units
1 to 10 units
1 to 12 units
Total system capacity range
50 to 130% of outdoor unit cap
50 to 130% of outdoor unit capacity *
1
acity *250 to 130% of outdoor unit capacity *2
Branching pipe
components
Branch header
(2 branches)
Branch header
(4 branches)
Branch header
(8 branches)
CMY-Y62-G-E
CMY-Y64-G-E
CMY-Y68-G-E
M series remote
controller
Model
Capacity
Cassette Ceiling
Ceiling
concealed
Wall
Mounted
Ceiling
Suspended
Floor standing
Ceiling concealed
Lossnay
CONNECTION KIT
2 by 2
4-way flow
2-way flow 1-way flow
Exposed
Concealed Fresh air
*
2
Built-in
PAC-LV11M-J
PLFY-P PLFY-P PLFY-EP*
6
PLFY-P PMFY-P
PEFY-P
PKFY-P
PCFY-P PFFY-P PFFY-P PEFY-P PDFY-P GUF*
4
15
15VFM-E1
–
–
–
–
15VMS1(L)-E
15VBM-E
–
–
–
–
–
–
20
20VFM-E1
20VEM-E
–
20VLMD-E 20VBM-E
20VMS1(L)-E
20VMA(L)-E
20VMR-E-L/R
20VBM-E
–
20VLEM-E
20VKM-E(2)
20VLRM-E
20VLRMM-E
–
20VM-E
–
25
25VFM-E1
25VEM-E
–
25VLMD-E 25VBM-E
25VMS1(L)-E
25VMA(L)-E
25VMR-E-L/R
25VMA3-E*
5
25VBM-E
–
25VLEM-E
25VKM-E(2)
25VLRM-E
25VLRMM-E
–
25VM-E
–
32
32VFM-E1
32VEM-E
–
32VLMD-E 32VBM-E
32VMS1(L)-E
32VMA(L)-E
32VMR-E-L/R
32VMA3-E*
5
32VHM-E
–
32VLEM-E
32VKM-E(2)
32VLRM-E
32VLRMM-E
–
32VM-E
–
40
40VFM-E1
40VEM-E
–
40VLMD-E 40VBM-E
40VMS1(L)-E
40VMA(L)-E
40VMH(S)-E
40VMA3-E*
5
40VHM-E
40VKM-E 40VLEM-E
40VKM-E(2)
40VLRM-E
40VLRMM-E
–
40VM-E
–
50
50VFM-E1
50VEM-E 50VEM-E 50VLMD-E
–
50VMS1(L)-E
50VMA(L)-E
50VMH(S)-E
50VHM-E
–
50VLEM-E 50VLRM-E
50VLRMM-E
–
50VM-E 50RD(H)4
63
–
63VEM-E 63VEM-E 63VLMD-E
–
63VMS1(L)-E
63VMA(L)-E
63VMH(S)-E
63VKM-E
63VKM-E 63VLEM-E 63VLRM-E
63VLRMM-E
–
63VM-E
–
71
–
–
–
–
–
71VMA(L)-E
71VMH(S)-E
–
–
–
–
–
71VM-E
–
80
–
80VEM-E 80VEM-E 80VLMD-E
–
80VMA(L)-E
80VMH(S)-E
–
–
–
–
80VMH-E-F 80VM-E
–
100
–
100VEM-E
–
100VLMD-E
–
100VMA(L)-E
100VMH(S)-E 100VKM-E 100VKM-E
–
–
–
100VM-E 100RD(H)4
125
–
125VEM-E
–
125VLMD-E
–
125VMA(L)-E
125VMH(S)-E
–
125VKM-E
–
–
–
125VM-E
–
140
–
–
–
–
–
140VMA(L)-E
140VMH(S)-E
–
–
–
–
140VMH-E-F
–
–
M series indoor unit
*
3
MSZ-GE Series
MSZ-SF Series
MSZ-EF Series
MSZ-FH Series
MSZ-LN Series
MSZ-AP Series
*
7