119
OCH668B
No.
SW1
setting
Display
mode
Display
on
the
LED1,
2
(display
data)
Notes
12345678
1
2
3
4
5
6
7
8
86
01
101010
IC1
TH22
(Liquid)
−99.9–999.9
(
:
)
(When
the
indoor
unit
is
not
connected,
it
is
displayed
as
0.)
Display
detected
data
of
indoor unit thermistors
87
11
101010
IC2
TH22
(Liquid)
88
0001
1010
IC3
TH22
(Liquid)
89
1001
1010
IC4
TH22
(Liquid)
90
0101
1010
IC5
TH22
(Liquid)
91
1101
1010
IC1 TH21
(Intake)
92
001
11010
IC2 TH21
(Intake)
93
101
11010
IC3 TH21
(Intake)
94
01
11
1010
IC4 TH21
(Intake)
95
11111
01
0
IC5 TH21
(Intake)
96
000001
10
Outdoor SC (cooling)
−99.9–999.9
(
:
)
Display
of
outdoor
subcool
(SC)
data
97
100001
10
Target
subcool
step
−2–4
Display
of
target
subcool
step
data
98
010001
10
IC1 SC/SH
−99.9–999.9
(
:
)
during
heating:
subcool
(SC)/during
cooling:
superheat
(SH)
(Fixed
to
"0"
during
cooling
operation)
Display
of
indoor
SC/SH
data
99
110001
10
IC2 SC/SH
100
001001
10
IC3 SC/SH
101
101001
10
IC4 SC/SH
102
01
1001
10
IC5 SC/SH
103
11
1001
10
Discharge
superheat
(SHd)
−99.9–999.9
(
:
)
Display
of
outdoor
discharge
superheat
(SHd)
data
105
100101
10
Target
Pd
display
(heating)
kgf/F
Pdm (0.0–30.0) (kgf/cm²)
Display
of
all
control
target
data
106
010101
10
Target
ET
display
(cooling)
ETm
(−2.0–23.0)
(
:
)
107
110101
10
Target outdoor SC (cooling)
SCm (0.0–20.0) (
:
)
108
001
101
10
Target indoor SC/SH (IC1)
SCm/SHm (0.0–20.0) (
:
)
109
101
101
10
Target indoor SC/SH (IC2)
11
0
01
1101
10
Target indoor SC/SH (IC3)
111
1111
011
0
Target indoor SC/SH (IC4)
11
2
00001
110
Target indoor SC/SH (IC5)
11
3
10001
110
Indoor
unit
check
stat
us
(IC9-12)
No.9
unit
check
No.10 unit check
No.1
1 unit check
No.12 unit check
Light on at time of abnormality
11
4
01001
110
Indoor
unit
operation
mode
(IC9-12)
No.9
unit
mode
No.10 unit mode
No.1
1 unit mode
No.12 unit mode
COOL/DR
Y: light on
HEA
T: light blinking
FAN/ST
OP: light of
f
11
5
11001
110
Indoor
unit
operation
display
(IC9-12
)
No.9
unit
operation
No.10 unit
operation
No.1
1 unit
operation
No.12 unit
operation
Thermo-ON: light on
Thermo-OFF: light of
f
11
6
00101
110
IC9
operation
mode
ST
OP
Fan
Cooling
Thermo-ON
Cooling
thermo-OFF
Heating
thermo-ON
Heating
thermo-OFF
Display
of
indoor
unit
operation
mode
11
7
10101
110
IC10
operation
mode
11
8
01
101
110
IC1
1 operation
mode
11
9
111
0111
0
IC12
operation
mode
120
0001
11
10
Target
indoor
SC/SH
(IC9)
SCm/SHm (0.0–20.0) (
:
)
Display
of
all
control
target
data
121
1001
11
10
Target indoor SC/SH (IC10)
122
0101
11
10
Target indoor SC/SH (IC1
1)
123
11
01111
0
Target indoor SC/SH (IC12)
124
00
11111
0
IC9
LEV
opening
pulse
abnormality delay
0–2000
(pulse)
Display
of
opening
pulse
of indoor LEV at time of abnormality delay
125
10
11111
0
IC10
LEV
opening
pulse
abnormality delay
126
0111111
0
IC1
1 LEV
opening
pulse
abnormality delay
127
1111111
0
IC12
LEV
opening
pulse
abnormality delay