II
Restrictions ]
- 19 -
HWE10190
GB
2) Remote controller wiring
*1 MA remote controller refers to MA remote controller (PAR-21MAA), MA simple remote controller, and wireless re-
mote controller.
*2 The use of cables that are smaller than 0.75mm
2
(AWG18) is recommended for easy handling.
*3 When connected to the terminal block on the Simple remote controller, use cables that meet the cable size specifi-
cations shown in the parenthesis.
[3] Switch Settings and Address Settings
1. Switch
setting
Refer to section "[5] An Example of a System to which an MA Remote Controller is connected " before performing wiring work.
Set the switches while the power is turned off.
If the switch settings are changed while the unit is being powered, those changes will not take effect, and the unit will not
function properly.
*1. The outdoor units in the same refrigerant circuit are automatically designated as OC and OS in the order of capacity
from large to small (if two or more units have the same capacity, in the order of address from small to large).
*2. Turn off the power to all the outdoor units in the same refrigerant circuit.
MA remote controller
*1
Cable type
Type
CVV
Number of
cores
2-core cable
Cable size
0.3 to 1.25mm
2
[AWG22 to 16] *2
(0.75 to 1.25mm
2
)
[AWG18 to 16] *3
Maximum overall line
length
200 m [656ft] max.
Units on which to set the switches
Symbol
Units to which the power must be shut off
Indoor unit
Main/sub unit
IC
Outdoor units
*2
and Indoor units
MA remote controller
Main/sub remote
controller
MA
Indoor units
Outdoor unit
*1
OC,OS
Outdoor units
*2
0000002115.book 19 ページ 2011年6月4日 土曜日 午前10時48分
Содержание PUHY-P250YJM-A
Страница 1: ......
Страница 11: ... 2 HWE10190 GB ...
Страница 25: ... 16 HWE10190 GB ...
Страница 45: ... II Restrictions 36 HWE10190 GB ...
Страница 47: ... 38 HWE10190 GB ...
Страница 57: ... 48 HWE10190 GB ...
Страница 69: ... IV Indoor Unit Components 60 HWE10190 GB ...
Страница 71: ... 62 HWE10190 GB ...
Страница 73: ... V Remote Controller 64 HWE10190 GB ...
Страница 75: ... 66 HWE10190 GB ...
Страница 82: ... 73 HWE10190 GB VII Refrigerant Circuit 1 Refrigerant Circuit Diagram 75 2 Principal Parts and Functions 78 ...
Страница 83: ... 74 HWE10190 GB ...
Страница 91: ... VII Refrigerant Circuit 82 HWE10190 GB ...
Страница 93: ... 84 HWE10190 GB ...
Страница 115: ... VIII Control 106 HWE10190 GB ...
Страница 117: ... 108 HWE10190 GB ...
Страница 137: ... 128 HWE10190 GB ...
Страница 225: ... X Troubleshooting 216 HWE10190 GB ...
Страница 226: ... 217 HWE10190 GB XI LED Monitor Display on the Outdoor Unit Board 1 How to Read the LED on the Service Monitor 219 ...
Страница 227: ... 218 HWE10190 GB ...
Страница 272: ......