15
•PFAV-P750VM-E
X1,X2,X4
Fuse<6.3A>
F1
F
Fuse<6.3A>
Contactor (Fan motor)
Thermistor(Supply air temp. detection)
TH21
Electronic linear expan. valve 3
LEV3
Electronic linear expan. valve 2
LEV2
Symbol
Name
Fan motor
Electronic linear expan. valve 1
Remote controller board
Liquid crystal monitor
Power source terminal bed
Transmission terminal bed
Varistor
Transformer
Symbol explanation
MA Remote controller terminal bed
M
R.B.
LCD
TB2
TB5
TB15
ZNR
T
LEV1
Contactor (Fan motor)
52F
51F
Over current relay(Fan motor)
CN33
Connector(Defrost output)
Thermistor(Piping temp. detection/gas)
Thermistor(Piping temp. detection/liquid)
Switch (For model selection)
SW7
SW1
SW14
SW12
SW11
SW4
SW5
SW8
Switch (For model selection)
Switch (Connection No. set)
Switch (For capacity code)
Switch (For four stages demand selection)
Switch (For mode selection)
Switch (2nd digit address set)
Switch (1st digit address set)
SW3
SW2
Switch (For mode selection)
TH22
TH23
TB6
Terminal bed(Indoor unit)
CN28
Connector(Fan failure)
SWE
SWC
Switch (For trial run)
Switch (For trial run of fan)
Switch (For mode selection)
Earth
Inside section of control box
LEV3
LEV2
LEV1
(Shield)
N
Indoor controller board No.2
31
1
2
3
4
5
6
SW14
SW12
SW11
Indoor/Outdoor
transmission line
M1
S
M2
2
1
CN2M
CNP
1
3
CN28
1
2
X4
t˚
t˚
t˚
TH21
TH22
TH23
21
21
CN21
21
CN20
CN29
CN3A
2
1
CN2M
CNP
1
3
SW8
SW5
13
1
3
CN33
ZNR
F
X06
X05
X04
7
13
5
CND
CN90
9
5
U
1
T
CN3T
31
CNT
2
3
4
5
U
6
M
7
CN7V
SWE
t˚
t˚
50/60Hz
380/400/415V
9
TH23
CN29
21
t˚
M
654321
SW4
X4
X2
52F
X1
F1
SW7
SW2
654321
CN60
X2
3
1
32
1
CN31
SW11
SW12
SW14
CN7V
654321
7
SW3
SW1
SWC
51F
CN31
1
2
3
Indoor controller board No.1
CN90
CND
CNT
CN60
CN20
SW5
1
1
5
2
2
3
1
3
4
1
5
6
L1
L2
TH21
SW2
SW7
1
3
CN3T
CN21
TH22
SWC
SW3
CN3A
1
2
SW4
Power supply
3N
~
7
X04
X05
X06
F
ZNR
L3
52F
1
2
3
4
5
6
T
CN33
3
1
CN28
3
1
1
2
M
M
3
1
3
1
2
1
2
X1
3
~
X4
51F
SW1
SW8
SWE
5
TB2
1
2 3
4 5 6
7
8
0
9
AB
CD
EF
8
7
6
5
4
3
2
1
0
9
1
2 3 4
5
6
7
8
9
0
TB5
0
9
8
7
6
5
4
3
2
1
9
0
1
2 3 4
5
6
7
8
F
E
D
C
B
A
9
0
8
7
6
5
4
TB15
Remote controller
LCD
TB6
R.B.
3
2
1
Note: 1. (Heavy dotted line):Field wiring
2. Have all electric work done by a licensed electrician according to
the local regulations.
3. Earth leakage circuit breaker should be set up on the wiring of the
power supply.
4. Mark indicates terminal bed, connector.
5. To enable the "auto recovery after power failure" function, set
SW1-9 of both No. 1 and No. 2 circuit boards to ON.
(Factory setting: OFF)
Содержание PUHY-P250YHM-A
Страница 1: ...Model PUHY P Y S HM A PFAV P VM E F DATA BOOK AIR CONDITIONING SYSTEMS ...
Страница 91: ...89 4 An Example of a System to which an MA Remote Controller is connected P750 P900 F models only ...
Страница 92: ...90 ...
Страница 93: ...91 L2 L31 L4 L32 200m 656ft ...
Страница 95: ...93 3 Emergency Operation Mode ...
Страница 96: ...94 ...
Страница 98: ...96 ...
Страница 99: ...97 ...