- 14 -
PFD-P500VM-E
t
t
t
t
t
t
t
t
1.
The dotted lines show field wiring.
2.
It is wiring for single refrigerant system at the time of shipping.
Change wiring and SW2, 3, 4 (No.1&No.2) as this figure in field
when you change it to two refrigerant circuit
3.
Set up the address of No.1 board in the odd number
, and set up the
address of No.2 board in the even number
.
But, set up the address of the No.2 board in the No.1 board +1.
4.
The outdoor unit to which the indoor unit is connected with the
transmission line, the address of the outdoor unit should be the
indoor unit +50.
5.
Mark indicates terminal bed, connector
, board insertion connector
or fastening connector of control board.
Note:
SW8
SW4
SW7
SW2
SWC
SW5
0
F E D C B A
9
0
9 8 7
6
5
4
3
2
1
9
1
2 3 4
5
6
78
0
87
6
5
4
3
21
65
74
3
2
1
CN24
CN25
1
2
2
1
X1
1
CN7V
Address (odd)
SW1
1
(1st digit)
SW12
(2nd digit)
SW14
No.1
CN51
CN52
Dehumidify
13
45
12
3
45
2
ZNR901
DSA1
ZNR1
F901
X06
X05
X04
X01
X07
CN3A
CN32
CN2M
I.B.1
3
2
1
2
3
2
1
1
59
15
1
37
3
1
CNT
CND
CN90
1
3
CN33
CNP
31
Z1
T
CN3T 31
CN28 21
CN31
1
2
3
21
CN29
3
2
22
1
1
1
CN20
CN21
CN60
CN22
2
1
654
Z3
33P1
SW1
SW3
TH24-1
TH21-1
TH22-1
TH23-1
LEV2
LEV1
1
2
3
4
5
6
6
5
4 3
2 1
AD.B.
6543
1
2
6543
1
2
6543
1
2
LEV1A
LEV1B
LEV1
2
1
Inside section of control box
RC
2
1
TB15
A1
S
B1
2
1
6
5
DC24~30V
No.1 Indoor unit Control wiring
LED display(No.1 failure)
LED display(status)
TB5-1
SHIELD
L3
L1
1
3
ZNR1
3
1
CN1
DSA1
S.B.
3
L3
L2
L1
1
2
N
F1
Power supply 3N~ 380/400/415V(50Hz) 400/415V(60Hz)
LED display(power supply)
PE
TB2
L5
3
4
5
6
Switch(normal/local)
SW9
No1.Failure output
Distant location on/of
f
<no voltage or current>
No1.Status output
Distant location on/of
f
<with voltage and current>
No2.Status output
No2.Failure output
Power supply DC30V
, AC100/200V
Power supply DC12~24V
LED display(No.2 failure)
DC24~30V
No.2 Indoor unit Control wiring
LED display(check)
L4
L2
L
L
L L
5
4
3
2
1
S
A2
B2
B2
B1
BC
A2
A1
AC
5
4
3
2
1
C
IFB
CN54
TB22
CN53
TB21
TB23
SHIELD
TB5-2
3
4
X1
1
1
2
PE
X12
<note2>
CN3A
1
CN2M
1 2 3
CN32
2
1
3
2
1
2
3
1
I.B.2
5
4
3
2
1
CN52
5
4
3
2
1
CN51
Dehumidify
ZNR901
F901
ZNR1
DSA1
X01
X07
X04
X05
X06
CNP
CN33
CN90
CND
CNT
CN3T
1
2
CN22
CN21
CN20
11
22
CN29
1
23
2
1
CN31
1
2
CN28
53
1
CN60
1
2
3
4
5
63
1
13
7
1
5
1
1
39
Z2
<note2>
33P2
T
Z3
CN25
CN24
1
2
CN7V
1
2
3
4
5
6
7
2
1
X12
SW5
SWC
SW12
(2nd digit)
SW1
1
(1st digit)
SW8
Address (odd)
SW3
SW1
SW2
SW7
SW4
SW14
0
F E D C B A
9
0
9 8 7
6
5
4
3
2
1
9
1
2 3 4
5
6
78
0
87
6
5
4
3
21
No.2
FA
N
over current
detection
51F
Z1
ZNR2
Z2
52F
Z3
TH24-2
TH21-2
TH22-2
TH23-2
51F
52F
MF
NAME
SYMBOL
Surge absorber
DSA1
L5
ZNR1, ZNR2, ZNR901
LED display (No.2 failure)
LED display (status)
LED display (check)
LED display (power supply)
MA
Remote controller
RC
TB21
TB15
TB5-1, -2
TB2
IFB
S.B.
AD.B.
I.B.1, I.B.2
MF
Surge absorber board
Switch (outlet/inlet temp.control)
Float switch
V
aristor
T
ransformer
Electronic linear expan.valve
Contactor(fan I/D)
Over current relay (fan I/D)
Thermistor (inlet temp.detection)
Switch (connection No.set)
Switch (for mode selection)
Switch (for capacity code)
Switch (for mode selection)
Switch (for model selection)
Auxiliary relay(check)
LED display (No.1 failure)
Switch (normal/local)
Refer to P55.
TH24-1, TH24-2
SW1(I.B.)
SW2(I.B.)
SW3(I.B.)
SW4(I.B.)
SW1
1(I.B.)
SW12(I.B.)
SW14(I.B.)
SWC(I.B.)
X1
1, X12
Z1, Z2
Z3
L1
L2
L3
L4
SW9
TH23-1, TH23-2
TH22-1, TH22-2
TH21-1, TH21-2
33P1, 33P2
51F
52F
LEV1, 2
T
F1
F901
TB23
TB22
Switch (1st digit address set)
Switch (2nd digit address set)
Fan motor
Indoor controller board
Adapter board
Power source terminal bed
T
ransmission terminal bed
External input/output board
T
ransmission terminal bed
T
e
rminal bed for distant location on/of
f
<With voltage and current>
T
e
rminal bed for distant location on/of
f
<No voltage or current>
Auxiliary relay(fan failure detection)
Auxiliary relay(fan)
Thermistor (piping temp.detection/gas)
Thermistor (piping temp.detection/liquid)
Thermistor (outlet temp.detection)
T
e
rminal bed for distant location display
Fuse <6.3/6A>
Fuse <5A>
(field supply
and construction)
Power
SW
Indoor unit
control board
Z
1(brown)
5(green)
CN52
The signal input of the dehumidify order is to
connect wiring referring to the bottom figure.
Relay circuit
External input adapter
(P
AC-SA88HA)
SW
:Defumidify order
Z:Relay (Contact : Minimum applicable load
DC12V 1mA
or less)
Distant control panel
Z
How to connect in case of two refrigerant circuit.
Remove the LEV1B connector
from AD.B.
board,
and
connect it to CN60 of
I.B.2 board.
Connect a connector to
CN3A, CN2M of I.B.2
board.
<note2>
6 5 4 3 2 1
CN60
654321
CN3A
CN2M
I.B. 2
1 2 3
2 1
LEV2
<note2>
How to set up to SW2, 3, 4.
(In case of two refrigerant circuit)
PFD-P500VM-E
(at the time of shipping)
ON
6
5
4
3
2
1
ON
6
5
4
3
2
11
0
9
8
7
ON
5
4
3
2
1
ON
5
4
3
2
1
10
9
8
7
ON
6
5
4
3
2
1
ON
6
5
4
3
2
1
T
wo refrigerant
circuit
Single refrigerant
circuit
SW2
SW3
SW4
External input-output
board (IFB)
The case of with-voltage input
...
A
The case of no-voltage input
....
B
When using the external input function on the indoor unit
that is connected to two-refrigerant circuits, connect the
short-circuit plate that is supplied with the unit to the
appropriate terminals on the external input-output board.
AC
A1
A2
BC
B1
B2
A
B
TB23
TB21
u
u
u
u
u
u