11
GB
Ŷ
9DQHVHWWLQJ
No setting
Step 1
Step 2
Step 4
Step 3
All
outlets
Draft
reduction*
Step 5
Press the [SELECT] button to save the settings.
A screen will appear that indicates the setting information is being trans-
mitted.
The setting changes will be made to the selected outlet.
The screen will automatically return to the one shown above (step 5)
when the transmission is completed.
Make the settings for other outlets, following the same procedures.
,IDOORXWOHWVDUHVHOHFWHG
ZLOOEHGLVSOD\HGWKHQH[WWLPH
WKHXQLWJRHVLQWRRSHUDWLRQ
Navigating through the screens
To go back to the Main menu ................ [MENU] button
To return to the previous screen .......... [RETURN] button
Ŷ
&RQ¿UPDWLRQSURFHGXUH
F1
F2
F3
F4
1
Manual vane angle
Input display:
Address
Check
M-NET address
Identify unit Check button
F1
F2
F3
F4
Manual vane angle
Return:
M-NET address
Function setting for unit
with vane fully open.
F1
F2
F3
F4
Manual vane angle
Return:
No communication
Check Unit state.
&DXWLRQ
7RSUHYHQWIDOOVPDLQWDLQDVWDEOHIRRWLQJZKHQRSHUDWLQJWKHXQLW
1
Select the "M-NET address" for
the units to whose vanes are to be
fixed, with the [F2] or [F3] button.
3UHVVWKH>)@EXWWRQWRFRQ¿UPWKH
unit.
2
After pressing the [F4] button, wait
approximately 15 seconds, and
then check the current state of the
air conditioner.
ĺ7KHYDQHLVSRLQWLQJGRZQZDUG
ĺ7KLVDLUFRQGLWLRQHULVGLVSOD\HG
on the remote controller.
ĺ$OORXWOHWVDUHFORVHGĺ3UHVV
the [RETURN] button and continue
the operation from the beginning.
ĺ7KHPHVVDJHVVKRZQWRWKHOHIW
DUHGLVSOD\HGĺ7KHWDUJHWGHYLFH
does not exist at this refrigerant
address.
3UHVV WKH >5(7851@ EXWWRQ WR
return to the initial screen.
3
Change the “M-NET address” to
the next number.
5HIHU WR VWHS
1
to change the
“M-NET address” and continue
with the confirmation.
2SHUDWLRQ
'L6HHVHQVRUVHWWLQJIRURQO\3/)<3
9)0(
'L6HHVHQVRUVHWWLQJ
F1
F2
F3
F4
Main
Main display:
Cursor
Page
Main menu
Maintenance
Initial setting
Service
F1
F2
F3
F4
Maintenance menu
Main menu:
Cursor
Auto descending panel
Manual vane angle
3D i-See sensor
F1
F2
F3
F4
3D i-See sensor
Cursor
Setting display:
Air distribution
Energy saving option
Seasonal airflow
$LUGLVWULEXWLRQ
F1
F2
F3
F4
Air distribution
Input display:
Address
Check
M-NET address
Identify unit Check button
1
Select “Maintenance” from the
Main menu (refer to page 8), and
press the [SELECT] button.
2
Select “3D i-See sensor” with the
[F1] or [F2] button, and press the
[SELECT] button.
3
Select the desired menu with the
[F1] or [F2] button, and press the
[SELECT] button.
$LUGLVWULEXWLRQ
Select the airflow direction control
method when the airflow direction
is set to “Auto”.
(QHUJ\VDYLQJRSWLRQ
Operates the energy-save mode
according to whether persons are
detected in the room by the 3D
i-See sensor.
6HDVRQDODLUIORZ
When the thermostat turns off,
the fan and the vanes operate
according to the control settings.
1
Select the M-NET address for the
units to whose vanes are to be
fixed, with the [F2] or [F3] button,
and press the [SELECT] button.
Press the [F4] button to confirm the
unit.
The vane of only the target indoor
unit is pointing downward.