<How to operate>
To change the air flow direction, press button.
NOTE
: Vane angle can be change to upper angle by cutting off the J5-3.
(Jamper resistance of indoor units)
(1) COOL/DRY operation
At the start-up of COOL or DRY operation, the airflow direction in automatically set to horizontal. After, it can be changed
to another direction with button on the remote controller.
<Auto return>
When 40° or 60° airflow is set with fan speed in LOW, “AUTO RETURN” appears below the room temperature display.
One hour later the direction changes to horizontal degrees, automatically and “AUTO RETURN” disappears.
(2) HEAT operation
At the start-up of HEAT operation, airflow direction depends on the setting of the last operation.
After, it can be changed to another direction with button. The airflow direction shifts to horizontal regardless of the
remote controller settings under any of the following conditions.
●
Thermostat OFF
●
Defrosting
●
Indoor fan speed EXTRA-LOW in hot adjustment
Available in COOL operation with fan speed on HIGH or in
HEAT operation.
Unavailable in DRY operation.
If fan speed changes from LOW to HIGH during 20°
downward airflow in COOL mode, the direction
automatically changes to horizontal.
Horizontal
1
20˚
2
40˚
3
60˚
4
swing
5
2-5 Auto vane control
FILTER
CHECK MODE
TEST RUN
4
Changes by pressing the button.