WIRING DIAGRAM
6
PCH-2GKHA
1
/PCH-2.5GKHA
1
/PCH-3GKHA
1
PCH-4GKHSA
1
/PCH-5GKHSA
1
/PCH-6GKHSA
1
240V
230V
220V
230V
220V
YELLOW
ORANGE
RED
1
ON
OFF
2 3 4
1
ON
OFF
2 3 4
[Emergency operation procedure]
(2) Turn on the outdoor unit side circuit breaker, then indoor unit side circuit breaker in this order.
(3) During emergency operation indoor fan runs at high speed but automatic vane remains stop.
(4) If vane closed, open the vane by hand slowly.
(5) Thermostat will not function. Cold air belows out for defrosting during heating thus do not operate defrosting for a long time.
(6) Emergency cooling should be limited to 10 hours maximum.
(The indoor unit heat exchanger may freeze).
(7) If the microcomputer doctor detects the abnormality of the drain-up machine during cooling mode, do not execute emergency
operation.(If causes drain overflow)
NOTES :
1. Since the indoor fan motor (MF 1.2) is connected with
230~240V power. IF 220V power is used. change the dip
switch (SWS<1.B>)on the indoor controller board showing
fig:
w
1.
2. Since the indoor transformer (T)is connected with
240Vpower.if 220.230V power is used. Change the wiring
connection showing fig:
w
2.
3. Since the outdoor side electric wiring may change be sure to check the outdoor unit electric wiring for servicing.
4. Indoor and outdoor connecting wires are made with polarities. make wiring matching terminal numbers.
5. Symbols used in wiring diagram above are.
: Connector,
/
/
: Terminal block.
6. Emergency operation
If remote controller or microcomputer fails but there is no other truble. emergency operation is possible by setting dip switch
(SW3<I.B>) on the indoor controller board.
[Check items]
(1)Make sure that no other trouble exist the outdoor unit. Trouble with the outdoor unit prevents emergency operation.
(If any trouble exists the outdoor unit error code “P8”will be displayed on the remote controller and the trouble position will be shown
on the outdoor controller LED. See electric wiring diagram of the outdoor unit for details.)
(2)Make sure that there is no trouble with the indoor fan.
Emergency operation will be continuous operation mode due to power ON/OFF (ON/OFF with the remote controller is not possible).
[Emergency operation procedure]
(1)Set the dip switch (SW3<I.B>) on the indoor controller board to
on and
off for cooling and
-
on for heating.
2
1
2
1
fig:
w
1
Indoor fan motor (MF) for
fig:
w
2
When power supply is
3
1
DS(OPTION)
DRAIN
CN50
54
3
2
1
BLK
GRY
(OPTION)
DP
6
HEA
TER
CN24
D.U.M
CNP
1
3
6GK(H)
5GK(H)
4GK(H)
1 2 3 4
OFF
ON
1 2 3 4
OFF
ON
ON
OFF
1 2 3 4
SW7
MODELS
3GK(H)
1 2 3 4
OFF
ON
1 2 3 4
OFF
ON
2.5GK(H)
2GK(H)
ON
OFF
1 2 3 4
SW7
MODELS
3
OFF
ON
1 2 3 4
TRANSMISSION WIRES
DC12V
14.3VAC
10VAC
1 3
TRANS
CNT
YL
W
WHT
240V
230V
220V
YL
W
T
RED
ORN
LED1 12V
POWER
VA
N
E
6
CN6V
1
LED2 5V
POWER
5
1
2
3
4
REMOCON
POWER
CN40
REMOTE CONTROLLER
INDOOR UNIT
OUTDOOR UNIT
TB5
1
2
1
2
BLK
BLK
RT2
ORN
BRN
GRN/YLW
N
L
L
N
TB2
POWER SUPPLY
~(1 PHASE)
AC220-240V 50Hz
AC220V 60Hz
3
5
BLU
RED
TB2
2
1
FS1
88H
BLU
RED
RED
H
FS2
6
GRY
1
RED
RED
88H
26H
5
PCH-2~6GKH(S)A (with heater)
1
6
YLW
YLW
2
I.B
X4
MF
2
1
BLU
BLU
1
2
CN22
TO
REMOCON
SW17
SW18
OFF
ON
4 3 2 1
R.B
CN2
3
1
2
5 4
1
2
ON
OFF
8 7 6 5 4 3 2 1
CN1
B.2
A.1
TB6
2
3
TO OUTDOOR UNIT
CONNECTING WIRES
DC12V
1
TB4
YLW
OUTDOOR
CN30
1
2
3
RT1
LOSSNA
Y
CN2L
CN20
PIPE
CN21
1
2
CN51
CENTRALL
Y
CONTROL
1
2
3
4
HEA
TER
CN24
DRAIN
CN50
INTAKE
SW3
SW7
1 2
4 5 6
9
7
10
8
J1
4
2
J9
SW6
1 2 3 4
2
J5
SW2
ON
OFF
1 2 3 4 5 6
X4
1 3 5
C
WHT
BLK
RED
I.B
FAN1
BG79Y189H03-A
ZNR
F2
F1
MV
4 3 2
1
1
3
POWER
TRANS
CND
CN4T
6
BRN
BRN
RED
RED
BLU
RED
SYMBOL
C
NAME
FAN MOTOR CAPACITOR
CN1<R.B>
PROGRAM TIMER CONNECTOR
CN2<R.B>
REMOTE SWITCH CONNECTOR
CN2L<I.B>
LOSSNAY CONNECTOR
CNP<I.B>
DRAIN-UP MACHINE CONNECTOR
CN50<I.B>
DRAIN SENSOR CONNECTOR
CN51<I.B>
CENTRALLY CONTROL CONNECTOR
F1,2<I.B>
FUSE(6.3A 250V)
FS1,2
H
HEATER
I.B
J1<I.B>
J5<I.B>
INDOOR CONTROLLER BOARD
FUNCTION SELECTOR JUMPER RESISTORS
MODEL SELECTOR JUMPER RESISTORS
SYMBOL
J9<I.B>
NAME
MODEL SELECTOR JUMPER RESISTORS
LED1<I.B>
DC 12V POWER LED
LED2<I.B>
DC 5V POWER LED
MF
FAN MOTOR
VANE MOTOR
REMOTE CONTROLLER BOARD
ROOM TEMPERATURE THERMISTOR
(0
:
/15k
"
, 25
:
/5.4k
"
DETECT)
INDOOR COIL THERMISTOR
(0
:
/15k
"
, 25
:
/5.4k
"
DETECT)
ADDRESS SELECTOR
EMERGENCY OPERATION SWITCH
TWIN/TRIPLE SELECTOR
MODEL SELECTOR
SYMBOL
SW17<R.B>
NAME
ADDRESS SELECTOR
SW18<R.B>
FUNCTION SELECTOR
T
TRANSFORMER
TB2
POWER SUPPLY TERMINAL BLOCK
INDOOR/OUTDOOR CONNECTING WIRE TERMINAL BLOCK
REMOTE CONTROLLER TERMINAL BLOCK
LINE TRANSMISSION
FAN MOTOR RELAY
VARISTOR
HEATER THERMAL SWITCH
HEATER CONTACTOR
OPTION DRAIN-UP MACHINE
OPTION DRAIN-UP SENSOR
THERMAL FUSE(98
:
10A:2GKHA / 117
:
16A:
4GKHA110
:
16A:2.5,3GKHA.5.6GKHSA)
MV
R.B
RT1
RT2
SW2<I.B>
SW3<I.B>
SW6<I.B>
SW7<I.B>
TB4
TB5,6
X4<I.B>
ZNR
26H
88H
DP
DS
Содержание PCH-2.5GKHA
Страница 2: ......