22
Compressor
Discharge
temperature
thermistor
RT61
R.V. coil
heating ON
cooling OFF
Refrigerant flow in cooling
Refrigerant flow in heating
Muffler
Outdoor
heat
exchanger
Muffler
LEV
Strainer
Defrost
thermistor
RT62
Capillary tube
{
4.0
✕
{
2.4
✕
300
(2pcs)
Capillary tube
{
3.0
✕
{
2.0
✕
200
Stop valve
Stop valve
(with service port)
4-way valve
Strainer
Indoor
heat
exchanger
Indoor coil
thermistor
RT12
(main)
Indoor coil
thermistor
RT13(sub)
Room
temperature
thermistor
RT11
Flared
connection
Flared
connection
Refrigerant pipe
[
15.88 (Option)
(with heat insulator)
Refrigerant pipe
[
9.52 (Option)
(with heat insulator)
Capillary tube
{
3.0
✕
{
2.0
✕
200
MSZ-G20SV -
E1
INDOOR UNIT
OUTDOOR UNIT
Unit:mm
MUZ-G20SV -
E1
MAX. REFRIGERANT PIPING LENGTH
Refrigerant piping
Max. length : m
A
12
15
Indoor unit
Gas 0.43
Liquid 0.5
Gas
9.52
12.7
15.88
Liquid
6.35
9.52
Outdoor unit
Piping size O.D : mm
Length of connecting pipe : m
Model
MSZ-G09SV -
E1
MUZ-G09SV -
E1
MSZ-G09SV -
E2
MUZ-G09SV -
E2
MSZ-G12SV -
E1
MUZ-G12SV -
E1
MSZ-G12SV -
E2
MUZ-G12SV -
E2
MSZ-G20SV -
E1
MUZ-G20SV -
E1
OB245 --1qxp 02.10.22 4:08 PM Page 22