24
The standard data contained in these specifications apply only to the operation of the air conditioner under normal conditions.
Since operating conditions vary according to the areas where these units are installed. The following information has been
provided to clarify the operating characteristics of the air conditioner under the conditions indicated by the performance curve.
(1) GUARANTEED VOLTAGE
207 ~ 253V, 50Hz
(2) AIR FLOW
Air flow should be set at MAX.
(3) MAIN READINGS
(1) Indoor intake air wet-bulb temperature :
°C WB
(2) Indoor outlet air wet-bulb temperature :
°C WB
(3) Outdoor intake air dry-bulb temperature :
°C DB
(4) Total input:
W
(5) Indoor intake air dry-bulb temperature :
°C DB
(6) Outdoor intake air wet-bulb temperature :
°C WB
(7) Total input :
W
Indoor air wet/dry-bulb temperature difference on the left side of the chart on this page and next page shows the differ-
ence between the indoor intake air wet/dry-bulb temperature and the indoor outlet air wet/dry-bulb temperature for your
reference at service.
}
}
Cooling
Heating
How to measure the indoor air wet-bulb / dry-bulb temperature difference
1. Attach at least 2 sets of wet and dry-bulb thermometers to the indoor air intake as shown in the figure, and at least 2 sets
of wet and dry-bulb thermometers to the indoor air outlet. The thermometers must be attached to the position where air
speed is high.
2. Attach at least 2 sets of wet and dry-bulb thermometers to the outdoor air intake.
Cover the thermometers to prevent direct rays of the sun.
3. Check that the air filter is cleaned.
4. Open windows and doors of room.
5. Press the EMERGENCY OPERATION switch once (twice) to start the EMERGENCY COOL (HEAT) MODE.
6. When system stabilizes after more than 15 minutes, measure temperature and take an average temperature.
7. 10 minutes later, measure temperature again and check that the temperature does not change.
INDOOR UNIT
OUTDOOR UNIT
Indoor air W
et-bulb temperature
difference (degree)
Indoor intake air W
et-bulb temperature (
:
)
Outdoor intake air Dry-bulb temperature (
:
)
Indoor intake air W
et-bulb temperature (
:
)
Outdoor intake air Dry-bulb temperature (
:
)
9.8
8.9
8.1
7.4
6.6
5.9
MSZ-G20SV -
E1
Rated frequency 120Hz
11.5
10.5
9.6
8.6
7.7
6.8
MSZ-G09SV -
E1
MSZ-G09SV -
E2
11.6
10.6
9.6
8.7
7.8
6.9
MSZ-G12SV -
E1
MSZ-G12SV -
E2
Rated frequency 85Hz
Rated frequency 79Hz
Wet and dry-bulb
thermometers
Wet and dry-bulb
thermometers
MSZ-G09SV -
MSZ-G09SV -
E2
E1
MSZ-G12SV -
MSZ-G12SV -
MSZ-G20SV -
E1
E2
E1
MUZ-G09SV -
MUZ-G09SV -
E2
E1
MUZ-G12SV -
MUZ-G12SV -
MUZ-G20SV -
E1
E2
E1
PERFORMANCE CURVES
8