background image

2

FRONT PANEL

ENCLOSURE

ENCLOSURE

AIR OUTLET

This air conditioner is NOT intended for use by children or infirm persons without supervisions.

Do not use intermediate connection of the power supply cord or the extension cord and do not
connect many devices to one AC outlet.

A fire or an electric shock may result from poor contact, poor insulation, exceeding the permissible
current, etc.

Do not scratch or process the power supply cord, etc.

Do not put heavy object on the power supply cord and do not scratch or process the cord. The cord may
be damaged and this may cause a fire or an electric shock.

Do not turn the breaker off/on or disconnect/connect the power supply plug during operation.

This may cause a fire due to spark, etc.

Be sure to turn off the breaker or disconnect the power supply plug absolutely after switching the indoor
unit off with the remote controller.

Do not expose your skin directly to cool air for a long time.

This could damage your health.

The customer should not install this unit.

If this is done incorrectly, it may cause a fire, an electric shock, or injury from the unit falling, water
leaking, etc. Consult your dealer.

Do not insert your finger or a stick, etc. into the air inlet/outlet.

Since the fan rotates at high speed, this may cause an injury.

Young children should be supervised to ensure that they do not play with the air conditioner.

When an abnormality (burning smell, etc.) occurs, stop the air conditioner and disconnect the power
supply plug or turn off the breaker.

If the unit continues to be operated in an abnormal condition, it may cause a fire, trouble, etc. In this case,
consult your dealer.

Repairs or relocation should not be done by the customer.

If this is done incorrectly, it may cause a fire, an electric shock, or injury from the unit falling, water
leaking, etc. Consult your dealer.

If the power supply cord is damaged, it must be replaced by the manufacturer or its service agent in order
to avoid a hazard.

When the air filter is to be removed, do not touch the metal parts of the indoor unit.

This may cause an injury.

Do not use an insecticide or flammable spray.

This may cause a fire or deformation of the cabinet.

Do not put a pet or houseplant where it will be exposed to direct airflow.

This could injure the pet or plant.

Do not leave the unit on an installation stand which is damaged.

The unit may fall and this may cause an injury.

Do not step onto an unstable bench when maintaining the unit, etc.

This may cause an injury, etc. if you fall down.

Do not pull the power supply cord.

The core wire of the power supply cord may be disconnected and this may cause a fire.

Do not charge or disassemble the batteries and do not throw them into a fire.

This may result in leakage, fire or an explosion.

Do not operate the unit for a long time in high humidity, e.g. leaving a door or window open.

In the cooling mode, if the unit is operated in a room with high humidity (80% RH or more) for a long time,
water condensed in the air conditioner may drop and wet or damage furniture, etc.

Do not operate the unit at low outside temperature (less than -10°C) in the cooling mode.

In the cooling mode, if the unit is operated at low outside temperature (less than -10°C), water con-
densed in the air conditioner may drop and wet or damage furniture, etc.

 

WARNING

 

CAUTION

CONTENTS

SAFETY PRECAUTIONS ........................................................................................................................................................ 2
NAME OF EACH PART ............................................................................................................................................................ 3
PREPARATION BEFORE OPERATION .................................................................................................................................. 4
I FEEL... AUTO OPERATION ................................................................................................................................................... 6
AUTO CHANGEOVER... AUTO MODE OPERATION .............................................................................................................. 7
MANUAL OPERATION (COOL, DRY, HEAT) ........................................................................................................................... 7
AIR FLOW VELOCITY AND DIRECTION ADJUSTMENT ...................................................................................................... 8
ECONO COOL OPERATION ................................................................................................................................................... 8
TIMER OPERATION (ON/OFF TIMER) ................................................................................................................................... 8
WHEN THE AIR CONDITIONER IS NOT GOING TO BE USED FOR A LONG TIME ............................................................ 9
MAINTENANCE ....................................................................................................................................................................... 9
CLEANING THE FRONT PANEL, HEAT EXCHANGER AND FAN ......................................................................................... 9
CLEANING THE CATECHIN AIR FILTER .............................................................................................................................. 10
REPLACEMENT OF THE AIR CLEANING FILTER ............................................................................................................... 10
CLEANING THE AIR OUTLET AND FAN OF THE INDOOR UNIT ....................................................................................... 11
BEFORE CONTACTING THE SERVICE REPRESENTATIVE, CHECK THE FOLLOWING AGAIN ...................................... 12
WHEN YOU THINK THAT TROUBLE HAS OCCURRED ...................................................................................................... 12
INSTALLATION, RELOCATION AND INSPECTION .............................................................................................................. 13
SPECIFICATIONS ................................................................................................................................................................. 13

SAFETY PRECAUTIONS

Since rotating parts and parts which could cause an electric shock are used in this product, be sure to read
these “Safety Precautions” before use.

Since the cautionary items shown here are important for safety, be sure to observe them.

Marks and their meanings

 WARNING:

Incorrect handling could cause a serious hazard, such as death, serious injury, etc. with a high prob-
ability.

 CAUTION:

Incorrect handling could cause a serious hazard depending on the conditions.

Meanings of symbols used in this manual

The colour of the sticker affixed to the unit is written in the parentheses.

:

Be sure not to do.

:

Be sure to follow the instruction.

(Black)

:

Never insert your finger or stick, etc.

(Black)

:

Never step onto the indoor/outdoor unit and do not put anything on them.

(Yellow)

:

Danger of electric shock. Be careful.

(Blue)

:

Be sure to disconnect the power supply plug from the power outlet.

(Blue)

:

Be sure to shut off the power.

After reading this manual, keep it together with the installation manual in a handy place for easy reference.

Warning mark positions

Содержание MSZ-A09YV SERIES

Страница 1: ...r gli utenti Per utilizzare correttamente quest unità leggere questo libretto d istruzioni atten tamente e per intero π π Àƒ π È ÙÔÓ ÂÏ ÙË È Ó ÚËÛÈÌÔ ÔÈ ÛÂÙ ٠ÙËÓ ÌÔÓ ÛˆÛÙ Î È Ì ÛÊ ÏÂÈ Â Èˆı Ù fiÙÈ ÂÙÂ È ÛÂÈ Ùfi ÙÔ ÂÁ ÂÈÚ ÈÔ Ô ËÁÈÒÓ ÚÈÓ fi ÙËÓ Ú ÛË INSTRUÇÕES DE OPERAÇÃO Para os clientes Para utilizar esta unidade correctamente certifique se de que lê estas instruções de operação antes da utiliza...

Страница 2: ...ing the unit etc This may cause an injury etc if you fall down Do not pull the power supply cord The core wire of the power supply cord may be disconnected and this may cause a fire Do not charge or disassemble the batteries and do not throw them into a fire This may result in leakage fire or an explosion Do not operate the unit for a long time in high humidity e g leaving a door or window open In...

Страница 3: ...ade the insulation This may cause an electric shock Do not step or put anything on the indoor outdoor unit This may cause an injury etc if you or something falls down WARNING Consult your dealer for installation of the air conditioner CAUTION Do not install the unit where flammable gas could leak If gas leaks and collects around the unit it may cause an explosion Earth the unit Do not connect the ...

Страница 4: ... because the setting of the unit needs to be changed Auto restart function is When the indoor unit is controlled with the remote controller the operation mode the set temperature and the fan speed are stored in the memory If a power failure occurs or the main power is turned off during operation Auto restart function sets automatically to start operating in the same mode as the one set with the re...

Страница 5: ...nce in case of EMERGENCY HEAT MODE or twice in case of EMERGENCY COOL MODE Operation Indicator Operation Indicator Operation Indicator EMERGENCY HEAT EMERGENCY COOL STOP Handling of the remote controller The range that the signal can reach is about 6 m when the remote controller is pointed at the front of the in door unit When a button is pressed one or two beeps will be heard from the indoor unit...

Страница 6: ...emperature is 2 C higher than the set temperature the set temperature may not be changed since the air conditioner is operating to reach the target set temperature In this case please wait until the room temperature drops to within 2 C of the set temperature and then change the set temperature HEAT When the room temperature is 2 C lower than the set temperature the set temperature may not be chang...

Страница 7: ... in sequence I FEEL AUTO COOL DRY HEAT To stop operation Press the ON OFF button After the operation mode is set once the operation starts in the same mode as the one set previously from the next time by simply pressing the ON OFF button MANUAL OPERATION COOL DRY HEAT ON OFF FAN TOO WARM TOO COOL VANE MODE ECONO COOL STOP START HR MIN AMPM CLOCK C AMPM I FEEL COOL DRY AUTO HEAT RESET CLOCK ON OFF ...

Страница 8: ...c How to set the ON timer 1 Press the START button during operation Each time the button is pressed the ON timer mode alternates between ON and OFF 2 Set the time of the timer using the HR and MIN buttons Each time the HR button is pressed the set time in creases by 1 hour each time the MIN button is pressed the set time increases by 10 minutes To release the ON timer Press the START button How to...

Страница 9: ...d both ends of the front panel lift the panel up until its level and then pull it to wards you CAUTION Do not drop the front panel or pull it out forcibly The panel may be damaged Do not step onto an unstable bench when removing or installing the front panel This may cause an injury etc if you fall down 2 Wipe the front panel with a soft dry cloth or wash it with water After washing the panel wipe...

Страница 10: ...l ter with water If the dirt is noticeable wash the filter with a solu tion of mild detergent diluted in lukewarm water If hot water 50 C or more is used the filter may be deformed Open the front panel then remove replace the filter Catechin air filter Remove Install What is Catechin air filter The air filter is dyed with a natural material catechin that is contained in tea The catechin air filter...

Страница 11: ...rmed and the vanes may not work properly Put the vertical vanes back correctly to their original positions Otherwise condensed water may drip down from the indoor unit or the horizontal vanes could malfunction 6 Install the horizontal vanes Reverse the removal procedures Upper vane Lower vane Insert this end first Upper right Insert this end first Lower right After Cleaning Insert the power supply...

Страница 12: ... power failure as these models are equipped with an auto restart function the air conditioner should start operating again Refer to Descrip tion of AUTO RESTART FUNCTION on page 6 Question The air flow direction changes during operation The direction of the hori zontal vane cannot be ad justed with the remote con troller Water leaks from the out door unit White smoke is discharged from the outdoor...

Страница 13: ...akage or not when repairs are carried out The refrigerant charged in the air conditioner is safe Refrigerant normally does not leak however if refrigerant gas leaks indoors and comes into contact with the fire of a fan heater space heater stove etc harmful substances will be generated Electrical work Provide an exclusive circuit for the power supply of the air conditioner Be sure to observe the br...

Страница 14: ...310 JAPAN SG79Y280H01 This product is designed and intended for use in the residential commercial and light industrial environment The product at hand is based on the following EU regulations Low Voltage Directive 73 23 EEC Electromagnetic Compatibility Directive 89 336 EEC ...

Страница 15: ......

Отзывы: